USR-DR504-E User Manual
Jinan USR IOT Technology Limited
Tech Support: h.usriot.com
20
Note: USR-cloud website :
Software schematic diagram:
Diagram 2.3.3-2 USR-Cloud
1. Open the dedicated setup software. Set the Serial port parameters according to the actual situation and click "Open
PC Serial".
2. Click "Enter Serial AT command mode" and wait for the device to enter AT command configuration mode.
3. Click "Query all parameters" and wait for obtaining all current parameters.
4. In the column "Choose Work Mode", select "Transparent Mode".
5. Set the parameters of SocketA, "IP&Port" is clouddata. usriot. com and 15000, and the connection type is "TCPC".
6. Open the "Enable Identity Package" function, the registry sending option is "Send registers data when socket
connects", registered type is "Cloud (for USR Cloud)", open the function of Cloud, and set the parameters (device ID and
the code need to log in to http://console. usriot. com/).
7. Set the parameters of APN.
8. Click "Save current parameters" to set and save all parameters.
9. Restart the module.