USR-LG220 User Manual
Technical Support:
h.usriot.com
Jinan USR IOT Technology Limited
www.usriot.com
8
Figure 7 Node active reporting mode general settings
Application ID: In HEX format and user should configure this to be same as LoRa node module which access
to LG220 network.
Gateway ID: LG220 unique identification ID and can’t be changed.
Number of nodes: Reserved accessing nodes. Number of nodes should be equal or greater than actual
accessing node.
Adjacent Nodes Time slot: Idle time from last node finish transmission to current node start transmission. This
parameter is to prevent reporting data interference between adjacent node and supports at most 65535ms.
Figure 8 Node active reporting mode channel settings
Note:
If user chooses ‘Update now’ and click ‘Save&Apply’, configuration will take effect after 10 seconds.
2.2.2.Polling waking mode
Polling waking mode: After configuring LG220 into this mode, LoRa modules which access LG220 network will
enter passive waking mode. LG220 will transmit lead code(Duration of lead code is same as waking period) to