NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE

;;;;;;;;;;;;;;;;;

;;;;;;;;;;;;;;;;;

;;;;;;;;;;;;;;;;;

;;;;;;;;;;;;;;;;;

;;;;;;;;;;;;;;;;;

;;;;;;;;;;;;;;;;;

;;;;;;;;;;;;;;;;;

;;;;;;;;;;;;;;;;;

;;;;;;;;;;;;;;;;;

;;;;;;;;;;;;;;;;;

;;;;;;;;;;;;;;;;;

;;;;;;;;;;;;;;;;;

;;;;;;;;;;;;;;;;;

;;;;;;;;;;;;;;;;;

;;;;;;;;;;;;;;;;;

;;;;;;;;;;;;;;;;;

;;;;;;;;;;;;;;;;;

;;;;;;;;;;;;;;;;;

L

C

L

C

Do not locate termination hood where ex-
cessive snow or ice buildup may occur.
Check vent termination area after snow-
falls, and clear to prevent potential block-
age of venting system.  When using snow
blowers, make sure snow is directed away
from the vent termination area.

18"

36"

36"

12"

12"

72"

48"

GM

R

6"

72"

72"

M

V

V

V

V

V

V

V

V

V

V

12"

From combustible's exterior surfaces, gas meter, air intakes, etc.

MINIMUM VENT TERMINATION CLEARANCES

The vent termination must not be lo-
cated:
1.

Less than 7 feet above a paved

sidewalk or a paved driveway

located

on public property.

2.

Within 6 feet of a mechanical air sup-

ply

inlet to any building.

3.

Above a meter/regulator assembly
within 3 feet horizontally of the verti-

cal

center-line of the regulator.

4.

Within 6 feet of any gas service

regulator vent outlet.

5.

Less than 1 foot above grade level;
(see section on below ground
installation for special venting.)

6.

Within the following distances of a
window or a door which can be

opened, any non-mechanical air

supply inlet or the combustion air in-

let

of another appliance;

a.

12 inches top and sides.

b.

4 feet below.

7.

Underneath a veranda, porch or deck
where,
a.

the veranda, porch or deck is fully

open on a minimum of two sides
beneath the floor.
b.

the distance between the top of

the vent termination and the under-

side

of the veranda, porch, or deck is

less

than 4 feet.

VENTING INSTRUCTIONS

The Model 9660 furnace is designed for
direct venting through a side wall or roof.
Only venting components specifically
approved and labeled for this furnace may
be used.  The flow of combustion and
ventilation air must not be obstructed.
Minimum clearance between vent pipes
and combustible materials is one (1) inch.

CAUTION: ALL JOINTS MUST
BE AIR-TIGHT.

THE INSTALLATION OF THIS
APPLIANCE MUST CONFORM WITH
LOCAL CODES, OR IN THE ABSENCE
OF LOCAL CODES, WITH THE LATEST
EDITION OF THE NATIONAL FUEL GAS
CODE, ANSI 223.1 (Latest Edition).

SIDE WALL VENTING

Location of Vent Termination

IMPORTANT:  The minimum clearances
given for the vent termination must be
strictly adhered to.  There must not be any
obstruction such as bushes, fences, garden
sheds, decks or utility buildings within 24"
from the front of the termination hood.

V -

Vent Termination

M -

Mechanical Air

GM-

Gas Meter

R -

Regulator

GLASS CLEANING

It will be necessary to clean the glass
periodically.  During start-up, condensation
forms on the inside of the glass and causes
dust, lint, etc. to cling to the glass surface.
This is normal.  Also, initial paint curing can
deposit a slight film on the glass.

DO NOT CLEAN GLASS WHEN IT IS
HOT.
DO NOT USE ABRASIVE CLEANERS ON
GLASS OR DOOR.

IMPORTANT!  THE VENT-AIR INTAKE
SYSTEM MUST BE PROPERLY IN-
STALLED TO INSURE PROPER AND
SAFE OPERATION.  THE VENT-AIR IN-
TAKE SYSTEM MUST BE PROPERLY
REINSTALLED AND RESEALED TO IN-
SURE PROPER AND SAFE OPERATION.
FOR MANUFACTURED HOME (MOBILE
HOME) INSTALLATION:  "THIS APPLI-
ANCE MUST BE INSTALLED IN ACCOR-
DANCE WITH THE MANUFACTURER'S
INSTRUCTIONS AND THE
MANUFACTURER'S HOME CON-
STRUCTION AND SAFETY STAN-
DARDS, TITLE  CFR,  PART  3280

."

Summary of Contents for 9660

Page 1: ...on may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplie...

Page 2: ...and liquids Do not use this appliance as a drying rack for clothing nor should Christmas stockings or decorations be hung in its immediate area 13 Do not operate this appliance without glass in place Replace damaged glass only with equivalent glass of equal thickness and size available from your dealer 14 Never burn solid fuel wood paper cardboard coal in this appliance 15 Do not use this applianc...

Page 3: ...O SCALE GAS FURNACE DIMENSIONS TOP VIEW FRONT VIEW SIDE VIEW 27 3 8 28 1 4 9 3 4 10 1 2 18 11 16 23 5 8 34 1 8 34 7 8 3 1 2 32 3 4 37 9 16 37 9 16 15 11 16 16 1 4 35 15 16 8 5 16 5 1 2 15 11 16 TOP VIEW SHOWN WITHOUT FURNACE TRIM FOR CLARITY ...

Page 4: ...tant paint or finish on the mantel to prevent discoloration Fig 3 Fig 4a Fig 5 34 1 8 37 3 8 15 11 16 11 1 2 12 37 3 8 12 37 3 8 15 11 16 16 o c 11 1 2 23 5 8 57 1 16 40 3 8 28 9 16 12 7 8 Fig 4b Minimum wall thickness 4 inches Maximum wall thickness 6 inches 10 8 6 4 2 18 16 14 12 10 WALL TOP OF GRILL OPENING Fig 6 Mantel Chart CLEARANCE TO COMBUSTIBLES BACK 0 inches from standoffs SIDES 0 inches...

Page 5: ...ve during any pressure testing of the gas supply piping system at test pressure equal to or less than 1 2 psig UNIT SIDE SEAL THIS AREA WITH HIGH TEMP CAULK PIPE COUPLING PIPE MANUAL SHUTOFF VALVE TEE JOINT PIPE NIPPLE CAP SEDIMENT TRAP Fig 7 INSTALLATION OF LOGS 1 Place large rear logs against back support bracket flat spots up 2 Place front log against front support bracket flat spots 3 Place sm...

Page 6: ...flame control DO NOT ALTER GAS ORIFICE Unless converting from LP to Natural or Vice Versa 4 Periodic visual checks of the Pilot Flame should be conducted to ensure that the flame is continuously present except when the valve knob is in the OFF position 1 To turn off the Main Burner only use Main Burner switch or turn Valve Knob to PILOT position SHUT DOWN PROCEDURE PILOT O F F PILOT O N Sit E A TP...

Page 7: ...660 furnace is designed for direct venting through a side wall or roof Only venting components specifically approved and labeled for this furnace may be used The flow of combustion and ventilation air must not be obstructed Minimum clearance between vent pipes and combustible materials is one 1 inch CAUTION ALL JOINTS MUST BE AIR TIGHT THE INSTALLATION OF THIS APPLIANCE MUST CONFORM WITH LOCAL COD...

Page 8: ...minimum clearances are applicable 2 2 12 12 48 48 24 12 12 36 48 48 6 6 2 2 6 6 INSIDE CORNER OUTSIDE CORNER INSIDE CORNER OUTSIDE CORNER RECESSED LOCATION RECESSED LOCATION BALCONY HOUSE EXTERIOR WALL BALCONY NO SIDE WALL CROSS SECTION BALCONY WITH PERPENDICULAR SIDE WALL BALCONY WITH PERPENDICULAR SIDE WALL 24 20 BALCONY NO SIDE WALL CROSS SECTION HOUSE EXTERIOR WALL BALCONY 24 18 SIDE WALL BALC...

Page 9: ...10 35 6 8 12 34 7 8 14 33 8 8 16 32 9 8 16 31 V V V 40 Max H 8 Max 1 1 1 T TABLE E H 12 Min H 24 Max TABLE F V H H H Min Max Max 1 2 2 2 4 4 3 6 6 4 8 8 5 8 10 6 8 12 7 8 14 8 8 16 9 8 16 V 20 Max H 8 Max H H H 16 Max 1 T 1 H TABLE D TABLE D H 12 Min H 24 Max TABLE B V H Min Max 1 2 2 4 3 6 4 8 5 8 V 40 Max H 8 Max T T H TABLE E TOP VIEW H H1 V HT TABLE F 1 H H1 V HT TABLE F 2 variation with 3 elb...

Page 10: ...heVent Termination to the exterior wall run a bead of non hardening mastic around it s outside edges so as to make a seal between it and the wall The arrow on the vent cap should be pointing up Insure that proper clearances to combustible materials are maintained Figure 14 1 The horizontal run of vent must have a 1 4 inch rise for every 1 foot of run towards the termination Never allow the vent to...

Page 11: ...ked position STEP 4 Cut a hole in the roof centered on the small drill hole placed in the roof in STEP 1 The hole should be of sufficient size to meet the minimum requirements for clearance to combustibles as specified on page 8 Continue to assemble lengths of Pipe and Elbows necessary to reach from the Ceiling Support Box up through the roof line A galvanized finish is desirable above the rooflin...

Page 12: ...e first floor including closets and storage spaces which the vertical vent passes through must be enclosed The enclosure may be framed and sheetrocked with stan dard construction materials see page 8 for minimum allowable clearance between the outside of the vent pipe and the com bustible surfaces of the enclosure Do not fill any of the required air spaces with in sulation IMPORTANT NOTICE If for ...

Page 13: ...xceed the length recommended in the Wiring Section Table and all connections are clean and tight Conduct each check shown in the chart below by connecting meter test leads to terminals as indicated All readings are closed circuit Component Connect Wall Meter See Check Meter Test Thermostat Reading Check Leads To Contacts Should Be Results Terminals Should Be Below Valve Operator Greater Than Syste...

Page 14: ... the base of the pilot and tighten nut 5 Next locate the conversion cap on the control and remove it Fig 22 6 Rotate the conversion cap until the desired gas designation is exposed and reinstall it in the control 7 Open glass door and remove the ceramic logs 8 Remove burner screw and then remove burner 9 Unscrew burner orifice and install orifice for the gas to be used as identified on the unit ra...

Page 15: ...o to spill switch wire 5 Thermopile is defective dirty or 5 Test with millivolt meter and replace weak if necessary 6 Thermopile is shorting out where it 6 Replace thermopile passes through cabinet 7 Gas valve will not prove pilot 7 Replace valve 8 Air in line 8 Purge air from gas line 9 Wire from valve to wall switch or 9 Remove wall switch wires from top remote switch is nicked or shorting and b...

Page 16: ... excess of 1 200 degrees Fahrenheit constant temperature The window only reaches between 500 600 degrees Fahrenheit Because of this it is almost impossible to bake something into the window Most things will with a little effort some off if you follow these directions Circulating fan speed does not vary Variable speed rheostat defective Replace rheostat NOTE Only replace rheostat with a rheostat su...

Page 17: ...these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life PILOT O F F PILOT O N Sit E A TP TH TP TH LIGHTING INSTRUCTIONS 1 STOP Read the safety information above on this label 2 Set the thermostat to lowest setting 3 Open lower door 4 Turn off all electric power to the appliance 5 Push in gas control knob slightly and turn clockwise to OFF N...

Page 18: ...USSC 18 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE MODEL 9660 GENERATOR REPAIR PARTS 19 20 21 22 1 16 17 3 2 18 12 10 11 13 14 9 7 5 15 4 6 8 ...

Page 19: ... Control Bracket 24241 1 11 Piezo Bracket w Screw 89760 1 12 Piezo w Nut 89761 1 13 Sit Control 81182 1 14 16ga Link Chain 86318 1 FT 15 Thermopile C43815 1 16 Sit Thermo Couple 89759 1 17 L P Sit Pilot 89757 1 Natural Gas Sit Pilot 89758 1 18 Generator Gasket 88086 1 8 x 1 2 Teks 83437 8 Piezo Cable 80375 1 Wire Assembly 80376 1 10 32 x 3 8 Machine Screw 83464 4 19 Top Fork Log 89771 1 20 Top Twi...

Page 20: ...USSC 20 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE MODEL 9660 GAS FURNACE REPAIR PARTS 1 3 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 23 4 24 25 22 26 27 31 30 29 28 2 7 ...

Page 21: ... Grill Hinge C18513 2 12 Firebox Bottom 24259 1 13 Firebox Divider 24250 1 Flue Outlet 89754 1 14 Firebox Wrapper 24253 1 Starting Collar 89756 1 15 Firebox Shield 24265 1 16 Firebox Top 24258 1 17 Latch w Keeper 89755 2 18 Insulation 24266 1 19 Firebox Front 24251 1 20 Inner Baffle 24279 1 21 Baffle Plate 24252 1 22 Vent Termination Assembly 68997 1 23 12 CO AX Pipe 89765 1 24 Insulation Shield 2...

Page 22: ... BRASS DOOR TRIM KIT MODEL RCK60 REMOTE CONTROL KIT REMOTE SKYTECH SKYTECH 1001 ON OFF INDICATOR R E M O T E NO OFF SKYTECH MODEL WSK60 WALL SWITCH KIT MODEL WTK60 WALL THERMOSTAT KIT 50 60 70 80 90 21 10 32 c 50 60 70 80 90 21 10 32 c MODEL FVK60 FULL VIEW DOOR KIT MODEL CBK60 REFRACTORY CERAMIC BRICK KIT ...

Page 23: ...R GENERATOR ASSEMBLY WHITE Neutral BLACK Hot GREEN Ground 2x4 BOX GREEN BLACK BLACK ATTACH GROUND TO SIDE OF UNIT WITH SCREW INCLUDED THERMO DISC 1 4 FEMALE INS 1 4 MALE INS 1 4 FEMALE INS BLOWER RHEOSTAT 1 4 MALE INS 1 4 MALE INS WHITE WHITE 80378 80378 80377 80377 CONTROL WIRING TERMINALS THERMOPILE ROCKER SWITCH ...

Page 24: ...kits can be used at a time Example If you have the Optional Remote Control Kit and the Optional Wall Switch Kit operation of the unit must be controlled by one or the other If you want to use the remote control simply turn the Wall Switch to OFF STANDARD WIRING FROM FACTORY WIRING OF THE RCK60 REMOTE CONTROL KIT WIRING WITH THE WTK60 WALL THERMOSTAT KIT PILOT O F F PILOT O N Sit E A TP TH TP TH RO...

Page 25: ...time Example If you want to control the operation of this unit with the Remote Control then you must turn the Wall Switch OFF When trying to use two Optional kits at once one will always override the other PILOT O F F PILOT O N Sit E A TP TH TP TH ROCKER SWITCH CONTROL VALVE REMOTE CONTROL SENSOR PIGGYBACK DISCONNECT 50 60 70 80 90 21 10 32 c 50 60 70 80 90 21 10 32 c WALL THERMOSTAT Note When com...

Page 26: ...USSC 26 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE NOTES ...

Page 27: ...USSC 27 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE NOTES ...

Page 28: ...RENCE WHEN WRITING ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION AS SHOWN IN THIS LIST 1 THE PART NUMBER 2 THE PART DESCRIPTION 3 THE MODEL NUMBER 9660 4 THE SERIAL NUMBER ____________________ UNITED STATES STOVE COMPANY 227 INDUSTRIAL PARK ROAD PO BOX 151 SOUTH PITTSBURG TN 37380 423 837 2100 DES...

Reviews: