3N0/3NK/3PD/3PG
2-3-15
YC3
1
PHADJ_MOT
2B
O
0/24V DC(pulse)
PUSLM drive control signal
Connected to
the punch
slide motor
2
PHADJ_MOT
1B
O
0/24V DC(pulse)
PUSLM drive control signal
3
PHADJ_MOT
2A
O
0/24V DC(pulse)
PUSLM drive control signal
4
PHADJ_MOT
1A
O
0/24V DC(pulse)
PUSLM drive control signal
YC4
1
PHMOT_N
O
0/24V DC(pulse)
PUM drive control signal
Connected to
the punch
motor
2
NC
-
-
Not used
3
PHMOT_P
O
0/24V DC(pulse)
PUM drive control signal
YC5
1
24V2
O
24V DC
24 V DC power output to PUSOL
Connected to
the punch
solenoid,
punch paper
edge
sensor1 and
punch tank
full sensor
2
PHSOL_PUL
O
0/24V DC
PUSOL: On/Off (activate)
3
PHSOL_RET
O
0/24V DC
PUSOL: On/Off (return)
4
PHLED_A
O
0/3.3V DC
PUPES1_A: On/Off
5
PHLED_B
O
0/3.3V DC
PUPES1_B: On/Off
6
PHLED_C
O
0/3.3V DC
PUPES1_C: On/Off
7
PHLED_D
O
0/3.3V DC
PUPES1_D: On/Off
8
PHLED_3.3V
O
3.3V DC
3.3 V DC power output to PUPES1
9
5.0V
O
5V DC
5 V DC power output to PUTFS
10
PHTNK_FUL
I
0/5V DC
PUTFS: On/Off
11
GND
-
-
Ground
YC6
1
SEN
O
3.3V DC
3.3 V DC power output to PUSLS
Connected to
the punch
slide sensor
2
GND
-
-
Ground
3
PHADJ_HP
I
0/3.3V DC
PUSLS: On/Off
YC7
1
PHPES_DET
I
0/3.3V DC
PUPES2: On/Off
Connected to
the punch
paper edge
sensor 2
2
GND
-
-
Ground
YC8
1
SENS3.3V
O
3.3V DC
3.3 V DC power output to PUPS
Connected to
the punch
plus sensor
and punch
home posi-
tion sensor
2
GND
-
-
Ground
3
PHMOT_PLS
I
0/3.3V DC
PUPS: On/Off
4
SENS3.3V
O
3.3V DC
3.3 V DC power output to PUHPS
5
GND
-
-
Ground
6
PHMOT_HP
I
0/3.3V DC
PUHPS: On/Off
Connector
Pin
Signal
I/O
Voltage
Description
Summary of Contents for AK 740
Page 1: ...Service Manual RFXPHQW LQLVKHU D 07 3 LUVW GLWLRQ Date 2 0 20 3 SM06 ...
Page 2: ...Service Manual RFXPHQW LQLVKHU D 07 3 LUVW GLWLRQ Date 2 0 20 3 SM06 ...
Page 4: ...Revision history Revision Date Pages Revised contents ...
Page 5: ...This page is intentionally left blank ...
Page 11: ...This page is intentionally left blank ...
Page 17: ...3N0 3NK 3PD 3PG 1 1 4 2 Mail box option Figure 1 1 2 1 2 1 Trays 1 7 2 Mailbox cover ...
Page 29: ...3N0 3NK 3PD 3PG 1 2 10 This page is intentionally left blank ...
Page 45: ...3N0 3NK 3PD 3PG 1 3 16 This page is intentionally left blank ...
Page 129: ...3N0 3NK 3PD 3PG 2 2 9 This page is intentionally left blank ...
Page 155: ...1 1 INSTALLATION GUIDE DF 791 3000 sheet finisher Installation Guide ...
Page 170: ...AK 740 Bridge unit Installation Guide ...
Page 172: ...MT 730 B Mail box Installation Guide ...