1-6-13 Removing the exposure lamp
1. Remove the ISU unit (see page 1-6-32).
2. Remove two connectors from the inverter
PWB.
3. Remove the screw and then remove the
inverter PWB.
Screw
Connectors
Inverter PWB
ISU unit
ISU unit
Exposure lamp mount
Hook
Figure 1-6-40 Removing the inverter PWB
4. While unhooking the hook and then slide the
exposure lamp mount.
Figure 1-6-41 Removing the exposure lamp mount