2DA/2DB
2-4-7
When maintenance item U092 (Adjusting the scanner automatically) is run using the specified original (P/N 2A068020), the follow
ing adjustments are automatically made:
•A
djusting the scanner center line (U067)
•A
djusting the scanner magnification in the main scanning direction (U065)
•A
djusting the scanner leading edge registration (U066)
•A
djusting the scanner magnification in the auxiliary scanning direction (U065)
When maintenance item U076 (Adjusting the DP automatically) is run using the specified original (P/N 2AC68241), the following a
djustments are automatically made:
•A
djusting the DP magnification (U070)
•A
djusting the DP scanning timing (U071)
•A
djusting the DP center line (U072)
Image quality
Item
S
pecifications
100% magnification
Copier: ±0.8%
Using DP: ±1.5%
Enlargement/reduction
Copier: ±1.0%
Using DP: ±1.5%
Lateral squareness
Copier: ±1.5 mm/375 mm
Using DP: ±3.0 mm/375 mm
Margins
A: 3.0
±
2.5 mm
B: 3.0 ± 2.5 mm
C: 3.0
±
2.5 mm
D: 3.0 ± 2.5mm
Leading edge registration
Drawer: ±2.5 mm
Bypass: ±2.5 mm
Duplex copying: ±2.5 mm
Skewed paper feed (left-right dif
ference)
Drawer: 1.5 mm or less
Bypass: 1.5 mm or less
Duplex copying: 2.0 mm or less
Lateral image shifting
Drawer: ±2.0 mm
Bypass: ±2.0 mm
Duplex copying: ±3.0 mm
Summary of Contents for cd 1116
Page 1: ...Service Manual Copy CD 1116 CD 1120 Rev 1 ...
Page 2: ...Service Manual Copy DC 2116 DC 2120 Rev 1 ...
Page 4: ...This page is intentionally left blank ...
Page 247: ...2DA 2DB 1 2 3 2 Figure 2 3 2 Power source PCB silk screen diagram 220 240 V AC 120 V AC ...
Page 264: ...2DA 2DB 1 2 3 19 Figure 2 3 10 Operation unit PCB silk screen diagram ...