10/12
4)
Clean the detector plate fitted at the
backside of the original table and the
board with alcohol and wipe them with a dry
cloth.
(Take care not to deform the detector plate
when cleaning it.)
Apply the gel type lubricant to the board.
(Refer to page 1 for details of where to apply
it, etc.)
*If the problem is not solved or a defect
occurs during this work, disconnect the
connector and release the hooks to remove
the board.
Part number of the board:
PARTS PWB SIZE DETECTION ASSY SP
(303M894270)
5) Supplementary
When reattaching the parts, make sure
that the wire is aligned inside the hook.
P
ARTS
T
ABLE
No.
Old Part
No.
New Part
No.
Description
Q’ty Compatibility
Affected model
Remarks
Old
New
Old New
1
-----------
302LC94790 GREASE FLOIL G-347CA(10G) SP
-
1
- O
Lubricant
10gram content
Hook
Detector plate
Board (pattern side)
Connector