2NM/2NX/2NY/2NZ/2P0/2P6
1-5-98
(4) Detaching and refitting the FAX control PWB (FAX model only)
Procedure
1. Remove the upper interface cover.
2. Release two hooks using a flat screw
driver and remove the right stay cover.
Figure 1-5-168
3. Remove two screws and then pull the
FAX control PWB out.
4. Check or replace the FAX control PWB
and refit all the removed parts.
Figure 1-5-169
Upper
interface cover
Flat screw driver
Right stay cover
Hooks
Screw
Screw
Fax control PWB
Summary of Contents for P-4030 MFP
Page 7: ...This page is intentionally left blank ...
Page 13: ...This page is intentionally left blank ...
Page 19: ...2NM 2NX 2NY 2NZ 2P0 2P6 5 Installation Guide PF 320 Paper Feeder ...
Page 55: ...2NM 2NX 2NY 2NZ 2P0 2P6 1 2 24 This page is intentionally left blank ...
Page 386: ...2NM 2NX 2NY 2NZ 2P0 2P6 1 5 100 This page is intentionally left blank ...
Page 486: ...Installation Guide PF 320 Paper Feeder Installation Guide ...
Page 487: ...PF 320 㾌㙼 㾌㙼 PF 320 PF 320 PF 320 㪧㪝㪄㪊㪉㪇 㪧㪝㪄㪊㪉㪇䈱 㪧㪝㪄㪊㪉㪇G 㾌 㾌 PF 320 PF 320 ...