3NY
1-3-7
2630
PF feed motor 4 error
(paper feeder 4)
When the PF feed motor is driven,
error signal is detected continuously
for 2 s.
Defective con-
nector cable or
poor contact in
the connector.
Reinsert the connector. Also check for
continuity within the connector cable.
If none, replace the cable.
PF feed motor 4 and PF main PWB
(YC6)
Defective drive
transmission sys-
tem of the PF
feed motor.
Check if the rollers and gears rotate
smoothly. If not, grease the bushes and
gears. Check for broken gears and
replace if any.
Defective PF
feed motor.
Replace the PF feed motor 4.
Defective PF
main PWB.
Replace the PF main PWB.
(See page 1-4-4)
Code
Contents
Causes
Check procedures/
corrective measures
Summary of Contents for PF 320
Page 1: ...Service Manual 3DSHU HHGHU 3 LUVW GLWLRQ Date 1 0 20 1 SM06 ...
Page 2: ...Service Manual 3DSHU HHGHU 3 LUVW GLWLRQ Date 0 20 1 SM06 ...
Page 4: ...Revision history Revision Date pages Revised contents ...
Page 5: ...This page is intentionally left blank ...
Page 11: ...This page is intentionally left blank ...
Page 13: ...3NY This page is intentionally left blank ...
Page 16: ...3NY 1 1 3 1 1 3 Machine cross section Figure 1 1 2 Machine cross section Paper path ...
Page 17: ...3NY 1 1 4 This page is intentionally left blank ...
Page 31: ...3NY 1 3 10 This page is intentionally left blank ...
Page 37: ...3NY 1 4 6 This page is intentionally left blank ...
Page 39: ...3NY 2 1 2 This page is intentionally left blank ...
Page 41: ...3NY 2 2 2 This page is intentionally left blank ...
Page 45: ...3NY 2 3 4 This page is intentionally left blank ...
Page 47: ...3NY 2 4 2 This page is intentionally left blank ...