1.1 Programming the NX-7002N via the LED keypad
1.1.1 Entering the program mode
To enter the program mode, press [*]-[8]. At this time, the five function LED’s (Stay,
Chime, Exit, Bypass and Cancel) will begin to flash. Next, enter the “Go To Program
Code” (factory default is [9]-[7]-[1]-[3]). If the “Go To Program Code” is valid, the “Service”
LED will flash and the five function LED’s will illuminate steady. You are now in the
program mode and ready to select the module to program.
Note: It is impossible to enter program mode if any partition or the system is
armed.
1.1.2 Selecting the module to program
Since all modules connected to the NetworX are programmed through the keypad, the
module you are programming should be the first entry. To program the NX-7002N
module, enter [7]-[8]-[#]. The [7]-[8] is the module number of the NX-7002N and the [#] is
the entry key.
1.1.3 Programming a location
Once the number of the module to be programmed has been entered, the “Armed” LED
will illuminate, indicating it is waiting for a programming location to be entered. Any
location can be accessed by directly entering the desired programming location followed
by the pound [#] key. If the location entered is a valid location, the “Armed” LED will
extinguish, the “Ready” LED will illuminate, and the zone LED’s will show the binary data
for the first segment of this location. While entering new data, the “Ready” LED will begin
flashing to indicate a data change in process. The flashing will continue until the new data
is stored by pressing the [*] key. Upon pressing the [*] key, the keypad will advance to the
next segment and display its data. This procedure is repeated until the last segment is
reached. Pressing the [#] key will exit from this location and the “Armed” LED will
illuminate again waiting for a new programming location to be entered. If the desired
location is the next sequential location, press the [Police] key. If the previous location is
desired press the [Fire] key. If the same location is desired press the [Medic] key. To
review the data in a location, repeat the above procedure, pressing the [*] key without any
numeric data entry. Each time the [*] key is pressed, the programming data of the next
segment will be displayed for review.
1.1.4 Exiting a location
After the last segment of a location is programmed, pressing the [*] key will exit that
location, turn the “Ready” LED off and the “Armed” LED on. As before, you are now ready
to enter another programming location. If an attempt is made to program an invalid entry
for a particular segment, the keypad sounder will emit a triple error beep (beep, beep,
beep) and remain in that segment awaiting a valid entry.