Site Specifications and Power Requirements
Power Requirements
Voltage
Frequency
Current (max with peripherals)
120 VAC ± 10%
50/60 Hz
5A
Site Wiring
A dedicated, unswitched power line is recommended. The AC outlet
should be close to the 2170 POS. Do not use extension cords.
Environmental Conditions
Temperature
Constant operation at or near the temperature limits stated below
should be avoided. Do not exceed the limits shown.
Operating temperature:
Storage temperature:
0°C to 40°C (32°F to 104°F)
-20°C to 60°C (-4°F to 140°F)
Humidity
Constant operation at or near the humidity limits stated below
should be avoided. Do not exceed the limits shown.
Humidity
Up to 90% non-condensing
Airflow Requirements
The ambient air temperature must not exceed 40°C (104°F).
Do not block the air vents on any side of the 2170 POS Workstation.
Airflow through these vents is required for system cooling.
Do not install the 2170 POS in a location not having sufficient
ventilation. Leave several inches of clearance on all sides where the
air vents are located.
AC Power Line and Data Line Transient Protection
The 2170 POS is a modern computer that can interface with a large variety of peripherals. This complete POS
system represents a significant financial investment for your site. As such, it must be protected against energy
transients (lightening strikes, switching transients), complete power loss or brownouts as you would protect any
piece of computer equipment. UTC RETAIL has a large variety of power and data line conditioner equipment and
uninterruptible power supplies (UPS) that can be sized for your system; contact your UTC RETAIL representative
for information.