14
electrIcal sectIon
ELECTRICAL WIRING
See wiring diagrams on the following two pages for
details.
Electrically bond boiler to ground in accordance with
requirements of authority having jurisdiction. Refer to:
USA- National Electrical Code, ANSI/NFPA 70.
•
Canada - Canadian Electrical Code, Part I, CSA C22.1:
•
Safety Standard for Electrical Installations.
THERMOSTAT INSTALLATION
Thermostat should be installed on an inside wall about
1.
four feet above the floor.
NEVER install a thermostat on an outside wall.
2.
Do not install a thermostat where it will be affected
3.
by drafts, hot or cold pipes, sunlight, lighting fixtures,
televisions, a fireplace, or a chimney.
Check thermostat operation by raising and lowering
4.
thermostat setting as required to start and stop the
burners.
Instructions for the final adjustment of the thermostat
5.
are packaged with the thermostat (adjusting heating
anticipator, calibration, etc.)
!
WARNING
Electrical shock hazard. Turn OFF electrical
power supply at service panel before making
electrical connections. Failure to do so could
result in death or serious injury.