124
124
(3) Cylinder Structure
(3) Cylinder Structure
1. Fixed Pin
1. Fixed Pin
--
T
Tank Loc
ank Locator
ator
5. Outlet Shut
5. Outlet Shut
--
off Valve
off Valve
2. LPG Level Gauge
2. LPG Level Gauge
6. Outlet Fitting
6. Outlet Fitting
--
LPG Hose
LPG Hose
3. Aux. Liquid Fill Valve
3. Aux. Liquid Fill Valve
7. Safety Relief Valve
7. Safety Relief Valve
4. Fixed Liquid Level
4. Fixed Liquid Level
9. Steps for Replacing the LPG Cylinder
9. Steps for Replacing the LPG Cylinder
Precautions
Precautions
1.
1. When replacing the
When replacing the LPG cylinder, be
LPG cylinder, be sure to wear
sure to wear canvas gloves
canvas gloves to protect from freez
to protect from freeze injuries caused
e injuries caused by
by
leaking LPG.
leaking LPG.
2.
2. When replacing the
When replacing the LPG cylinder, do
LPG cylinder, do so in a
so in a fully-ventilated, well-lit place.
fully-ventilated, well-lit place. Smoking is
Smoking is strictly prohibited.
strictly prohibited. Avoid
Avoid
all other open flames and sources of ignition.
all other open flames and sources of ignition.
3.
3. When filling with
When filling with LPG cylinder, lay
LPG cylinder, lay the cylinder flat
the cylinder flat and set the LPG i
and set the LPG inflow shut-off valve to the top.
nflow shut-off valve to the top. Twist off the
Twist off the
dust cover from the inflow shut-off valve. Insert the charging connector, and open the LPG inflow shut-off valve.
dust cover from the inflow shut-off valve. Insert the charging connector, and open the LPG inflow shut-off valve.
When the LPG has been filled to about 80% of the tank
When the LPG has been filled to about 80% of the tank
’
’
s capacity, remove the filling head. When you fill to 80%
s capacity, remove the filling head. When you fill to 80%
of rated capacity, the charge-limiting device may automatically shut down. After filling has been terminated,
of rated capacity, the charge-limiting device may automatically shut down. After filling has been terminated,
remove the filling head. Twist the filling valve dust cover until tight. Tighten the inflow shut-off valve.
remove the filling head. Twist the filling valve dust cover until tight. Tighten the inflow shut-off valve.
Check to
Check to
make sure all components and parts are in good condition and undamaged.
make sure all components and parts are in good condition and undamaged.
4.
4. Use
Use the
the safe
safe operating procedures
operating procedures per y
per your l
our local
ocal regulations.
regulations.
https://www.forkliftpdfmanuals.com/
Summary of Contents for UT25C
Page 85: ...79 79 10 Labels 10 Labels https www forkliftpdfmanuals com ...
Page 90: ...84 84 7 7 Tip Over Warning Label Tip Over Warning Label https www forkliftpdfmanuals com ...
Page 119: ...113 113 https www forkliftpdfmanuals com ...
Page 139: ...133 133 IMPCO Single Fuel System IMPCO Single Fuel System https www forkliftpdfmanuals com ...