Motion Sensor Light
Control
© 2007 HeathCo LLC
598-1292-03
Light Control
Sensor
Cover
Plate
Bulb Holders
2 Wire
Connectors
6 Screws
(3 sizes included)
Gasket
2 Shells
Questions or problems? Before returning to your re-
tailer, refer to the troubleshooting guide in this manual
or call our technical service department at 1-800-858-
8501 (English speaking only), 7:30 am to 4:30 pm, CST,
Monday – Friday.
Features
• D
ual
Z
one
™ Technology.
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• D
ual
B
rite
®
Timer.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
Requirements
• The light control requires 120-volts AC.
• If you want to use the Manual Mode, the control must
be wired through a switch.
•
Some codes require installation by a qualified
electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
Mounting Bolt
Mounting Strap
Rubber Plug
Plastic Hanger
TEST
TEST 1 5 20
ON-TIME
Off 3 6 Dusk to
Dawn
D
ual
B
rite
®
Put ON-TIME switch
on the sensor bottom
to TEST and the D
ual
-
B
rite
®
switch OFF.
OPERATION
* resets to Auto Mode at dawn.
MANUAL MODE
ON-TIME
TEST
1 5 20
... back on.
AUTO
1 Second OFF
then...
Note: When first turned on wait about 1
1
/
2
minutes for
the circuitry to calibrate.
Package Contents
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 20
position.
Put the ON-TIME switch in the 1, 5,
or 20 minute position.
Items
Models
247580
UT-5105-BZ
182155
UT-5105-WH
Mode:
On-Time
Works:
Day Night
Test
5 Seconds
x
x
Auto
1, 5, or 20 Min
x
Manual
To Dawn*
x
Accent
3, 6 Hr, to Dawn
x
Meets the ENERGY STAR
®
guidelines
when D
ual
B
rite
®
function is off and
ON-TIME is 1 or 5 minutes and when
used with 120 W Max bulbs.