Timer Operation

1. While the unit is ON, press the Timer button until the Timer-OFF light illuminates. To set the  

 

  auto-OFF time, 

   

a. Use the Up and Down buttons to adjust the timer settings in half-hour increments up to 10  

   

  hours and one-hour increments up to 24 hours.

   

b. Wait five seconds to accept the setting.

2. While the unit is OFF, press the Timer button until the Timer-ON light illuminates. To set the  

 

  auto-ON time, follow steps 1a and 1b.

Auto-Restart

The auto-restart feature allows the unit to restart after a power interruption using the previously 

programmed settings. To protect the unit, the compressor will not restart until three minutes after 

stopping.

Draining Excess Water

While most water condensed by the unit is exhausted via the self-evaporative system, the unit has 

two backup methods for draining water if necessary. 

1. To drain excess water with a drain hose,

   

a. Remove the upper drain outlet cover in the middle rear of the unit.

   

b. Attach the drain hose to the outlet.

   

c. Place the opposite end of the drain hose over a drain.

2. To drain excess water directly below the unit, 

   

a. Position the unit over a drain.

   

b. Remove the lower drain outlet cover and plug at the bottom rear of the unit.

Cleaning the Air Filter

Clean the air filter every two weeks to ensure optimal operation.

1. Power OFF the unit. 

2. Remove the grille on the rear of the unit and slide out the air filter to remove it.

3. Rinse the filter in warm water and allow it to dry completely before replacing it.

Storing the Unit

1. Drain the unit completely using the drain outlets on the rear of the unit.

2. Run the unit on fan mode for 12 hours to ensure the inside of the unit is dry.

3. Power OFF and unplug the unit.

4. Clean the air filter.

5. Remove the batteries from the remote controller.

Error Codes

The following error codes may appear on the unit’s display panel.

Error Code

Cause

Solution

E1

Room temperature sensor error

Disconnect the unit from the 

power source and reconnect it. If 

the problem persists, the unit may 

require service. See 

warranty information.

E2

Evaporator temperature sensor error

E3

Condensor temperature sensor error

E4

Display panel communication error

P1

Bottom tray is full

Drain the unit using the 

outlets on the back of the unit (see 

“Draining Excess Water” section).

Operating Instructions

Summary of Contents for Portable A/C

Page 1: ...ppliances open flame or combustible liquid Do not operate where water may be spilled or sprayed on the unit Operate move and store the unit upright at all times Allow at least 10 of space around the u...

Page 2: ...nt control 10 Air inlet 11 Air filter 12 Drain outlet 1 Drain hose 3 Foam seals 2 Exhaust intake hoses and adapters 1 Remote controller with batteries 1 Portable A C unit 1 Window slider kit and retai...

Page 3: ...he length of the kit to fit the opening using the retainer to lock the kit at the desired length Insert the window slider kit into the window frame Adjust the height of the kit to fit the opening usin...

Page 4: ...tton Press to select the fan speed low medium high or auto The illuminated fan speed icon indicates the selected setting Fan speed can only be adjusted in cooling dehumidifying and fan modes Hold for...

Page 5: ...Press the Mode button until the cooling indicator light illuminates 2 Press the Up or Down button to raise or lower the set temperature by 2 F within the range of 62 to 88 F 17 to 31 C 3 Press the Fa...

Page 6: ...drain excess water directly below the unit a Position the unit over a drain b Remove the lower drain outlet cover and plug at the bottom rear of the unit Cleaning the Air Filter Clean the air filter...

Page 7: ...or injury caused to other products machinery buildings or property loss of profits time or product or inconvenience The original proof of purchase MUST accompany the Utopian Systems product for this...

Page 8: ......

Reviews: