background image

7

Operation Tips

The following events may occur during normal operation.

1. The compressor will not restart immediately after being stopped.

      • To protect the compressor, it cannot restart for 3-4 minutes after it stops.

2. The indoor unit produces a white mist.

      • The unit may generate white mist during cool mode if the room has a high relative humidity and there is   
        a large temperature difference between the air inlet and air outlet.
      • The unit may produce white mist during heat mode after defrosting because of the moisture generated. 

3. The air conditioner produces a low noise.

      • The air conditioner may produce a low hissing sound when the compressor is running or has just stopped  
        running. The sound is caused by the refrigerant flowing or coming to a stop.
      • The air conditioner may produce a low squeaking noise when the compressor is running or has just  

 

        stopped  running. The sound is caused by heat expansion and cold contraction of the plastic parts in the    
        unit when the temperature changes.
      • The louver may produce a noise as it returns to its original position when the air conditioner is turned on.

4. The indoor unit blows out dust.

      • It is normal for the air conditioner to blow out dust when it has not been used for a long time or during    
        first use of the unit.

5. The indoor unit produces an unusual smell.

      • The indoor unit may give off smells absorbed from building material, furniture or smoke.

6. The air conditioner switches to fan-only mode from cool or heat mode.

      • When the indoor temperature reaches the temperature setting on the air conditioner, the compressor will  
        stop  automatically, and the air conditioner will switch to fan-only mode. The compressor will start again    
        when the indoor temperature rises or falls.

7. Condensation forms on the indoor unit.

      • Condensation may form on the indoor unit during cool mode if relative humidity is higher than 80%.  

 

        To reduce condensation, adjust the horizontal louver to the maximum air outlet position and select high   
     fan speed.

8. A power failure during operation stops the unit completely.

      • When the power is restored, the auto-restart function restarts the unit with all the previous settings 
        preserved by the memory function.

9. The unit malfunctions without apparent cause.
 

    • Lightning or a signal from a wireless phone may cause the unit to malfunction. Disconnect the unit from    

        the power source, then reconnect it. Push the on/off button on the remote controller to restart operation.

Summary of Contents for Split A/C

Page 1: ...rk must be performed by a licensed professional This appliance should not be used by individuals who lack the experience knowledge or ability to safely operate this appliance unless they receive super...

Page 2: ...breaker Do not place a heater or other appliances near the power cable Do not disassemble or modify unit If flammable gas leaks turn off the gas and open a window to ventilate the room before turning...

Page 3: ...s per second when safety protection features are operating 1 AUTO indicator This indicator illuminates when the air conditioner is in auto operation 2 DEFROST indicator This indicator illuminates when...

Page 4: ...condensation set the vertical airflow louver to the maximum opening and set fan mode to high 1 Lift the front panel until it remains fixed at an angle with a clicking sound 2 Push the manual control...

Page 5: ...tion CAUTION Auto Operation When the air conditioner is in auto mode it will automatically select between cooling heating and fan only operation to meet the set operating temperature Select desired se...

Page 6: ...duster to clean the unit Do not use benzene thinner polishing powder or similar solvents for cleaning These may cause the plastic surface to crack or deform Never use water hotter than 104 F 40 C to c...

Page 7: ...unit blows out dust It is normal for the air conditioner to blow out dust when it has not been used for a long time or during first use of the unit 5 The indoor unit produces an unusual smell The ind...

Page 8: ...ut Wait for power to be restored Unit has become unplugged Plug unit securely into wall outlet Fuse has blown Replace the fuse Battery in remote controller has been exhausted Replace the battery The t...

Reviews: