4
Operating Instructions
Timer Operation
1.
When the unit is on
, press the TIMER button until the timer-off light illuminates. To set the
auto- off time, use the UP and DOWN buttons to adjust the timer setting in increments of 0.5
hours up to 10 hours and 1 hour up to 24 hours. To set the auto-on time, press the TIMER button
again until the timer-on light illuminates and use the UP and DOWN buttons to adjust the timer
setting. Wait 5 seconds to accept the setting.
2.
When the unit is off
, press the TIMER button until the timer-on light illuminates. To set the
auto- on time, use the UP and DOWN buttons to adjust the timer setting in increments of 0.5
hours up to 10 hours and 1 hour up to 24 hours. To set the auto-off time, press the TIMER button
again until the timer-off light illuminates and use the UP and DOWN buttons to adjust the
timer setting. Wait 5 seconds to accept the setting.
Emptying the Water Tank
1. When the water tank is full, the unit beeps eight times, the full light blinks and “P2” appears on
the display. If the unit is on, the compressor turns off and the fan runs for 30 seconds to dry
the condenser.
2. Grip the handles on the tank’s sides and slowly pull it out. Do not place the tank on the floor
because its uneven bottom may cause it to spill.
3. Empty the tank and carefully replace it in the unit.
Continuous Drainage
1. To continuously drain water from the unit, remove the water tank and the cover from the
drainage outlet on the back of the unit.
2. Attach the drain hose to the drainage adapter.
3. Insert the other end of the drain hose through the drainage outlet and attach it to the
connector at the right front of the unit.
Note:
Ensure the drain hose fits securely to the connector.
4. Use the provided screws to secure the drainage adapter to the unit.
5. Attach a
5
/
16
” ID water hose (available separately) to the drainage adapter and place the other
end over a drain.
6. Carefully replace the tank in the unit.
7. Remove the drain hose from the outlet and replace the outlet cover when the continuous
drainage function is not in use.
Auto-Shutoff
The unit will turn off 30 seconds after the water tank reaches capacity. The unit will also turn off
automatically when the set humidity level is reached.
Auto-Defrost
When frost builds up on the evaporator coils, the compressor will turn off and the fan will
continue to run until the evaporator coils have defrosted.
Auto-Restart
The Auto Restart feature allows the unit to restart after a power interruption using the previously
programmed settings. To protect the unit, the compressor will not restart for 3 minutes
after stopping.