ϳ
c) Optimizing System Performance
The UV lamps and their corresponding quartz sleeves need to be maintained. As a general rule, the lamps
need to be changed after a year of usage (10,000 hours). Quartz sleeves should be changed every three (3)
to five (5) years or sooner if damaged.
Quartz sleeves also need to be cleaned on a periodic basis based on real world plant conditions. The
factory recommends using denatured alcohol or a commercially available non-abrasive cleaning product. In
addition to cleaning, please remember to wear gloves when handling lamps and sleeves. It is important that
the cleaning product you select leaves no residue.
d) Environmental Issues Relating to UV Lamps
UV lamps need to be recycled like fluorescent lamps because they contain mercury. Please
follow your local recycling laws. Please visit
www.lamprecycle.org
for help finding a recycling
center in your area. In the event that you are unable to find a disposal location, please
contact manufacturer’s representative.
e) Receiving UV Equipment and Spare Parts
Inspection of the UV equipment must be made immediately upon receipt for damage and verification of
contents. It is important to compare the contents of your shipment to the actual packing list. Any
deviations must be brought to the factory’s attention. Additionally, lamps and quartz sleeves need to be
inspected for damage. If shipment or parts are damaged, immediately contact factory and hold broken
contents and their containers for inspection by shipping company. Failure to make a damage claim within 2
business days of receipt of product can result in loss of claim.
f) Electrical Configuration
The UV disinfection system uses sophisticated electronics and specialty lamps. The UV system’s electronics
requires clean power. The system has been designed to use a certain specified voltage. UV equipment must
be protected from surges. If the plant is susceptible to brownouts, please contact factory.
Do not exceed 3 ON/OFF cycles per 24-hour operation. Excessive cycling of the UV system will cause the
UV lamps to age prematurely.
Summary of Contents for LEOPARD UV Series
Page 2: ......
Page 6: ......
Page 35: ......
Page 40: ...Replacement Parts List Electrical Enclosure Leopard Series Short Long Chambered Systems...
Page 43: ...Model Number __________ Serial Number __________...
Page 44: ...d Z s K D s s hs Y W K K Z K Z K t W W Z s s hs D Z s Z hs hs...
Page 46: ...EKd...
Page 47: ......