c) Lamp Out Alert (Optional)
For models equipped with Lamp Out Alert ballast(s), connect your external control (PLC or SCADA) to the
bottom of the enclosure via the auxiliary connection.
Warning!
Control signal may not exceed 32V AC, 50V DC, 50mA current
d) Chamber
Minimum Clearance
Ensure that you have adequate space on the lamp side of the treatment chamber to insert and
remove the quartz sleeve and UV lamp(s).
·
40” or more is preferred for short chambers
·
70” or more is preferred for long chambers
If thought is not given to this aspect, the lamps and quartz sleeves will be impossible to install.