CAUTION:

UVC-Equipment Damage Hazard.
1.   Ultraviolet light can cause color shift or structural degradation of plastic materials
2.  Ultraviolet light can cause color shift or structural degradation of resin materials
3.  Ultraviolet light can cause color shift or structural degradation of leatherwear
4.  Ultraviolet light can cause color shift or structural degradation of organic compounds materials

OZONE-Equipment Damage Hazard.
1.   OZONE can cause color shift or structural degradation of plastic materials
2.  OZONE can cause color shift or structural degradation of resin materials
3.  OZONE can cause color shift or structural degradation of leatherwear
4.  OZONE can cause color shift or structural degradation of organic compounds materials
5.  High concentrations of ozone for a long time can cause electronic products function damage

       NOTES:

1.   The design of this product based on IEC 62471:2006 Photobiological safety of lamps and lamp 

systems and other international standards

2.  This product utilizes the ultraviolet rays LED , which emits UV-C rays with peak value wave length at 

275nm to disinfect

3.  Ultraviolet LED is a relatively tight and fragile electronic component, users should avoid the impact on 

the product resulting in product failure.

4.  The design of this product is according to Code of Federal Regulations Title 21, Volume 8 by US FDA, 

California Code of Regulations Title 17 Public Health, and IEC 62368-1[4] 7.3 and other international 
standards

5.  According to code of federal Regulations Title 21, Volume 8, ozone is a toxic gas, according to the FDA. 

Although ozone has been reported to have adverse physiological effects on the central nervous 
system, heart and vision, its main physiological effect is to stimulate the mucous membranes. 
Inhalation of ozone causes enough irritation to the lungs, leading to pulmonary edema. The onset of 
pulmonary edema is usually delayed by several hours after exposure; As the hazards of ozone are 
widely understood, people pay full attention to the use of ozone.

6.  At Ozone concentrations of 0.02PPM (0.04mg/m³), ozone can be smelled by people with acute 

olfactory senses, at 0.15PPM (0.32mg/m³), ozone can be smelled by the general population, at 
1-10PPM (2.14 - 21.4mg/m³) ozone has reached the "stimulus range", and can be clearly smelled, at 
10PPM (21.4mg/m³) ozone has reached the "toxic range" or more "poisonous range". The odor of ozone 
is not a reliable warning indicator due to the possibility of olfactory fatigue

7.  Long term occupied enclosed spaces, such as houses, apartments, hospitals and offices, should have 

ozone volumes below 0.1mg/m³ (0.05PPM). The ozone concentration in the workplace, i.e. 
occupational exposure limit, is 0.1PPM

8.  The amount of space used by the equipment used to place and use this device should not be less than 

20m³ to ensure that the ozone remaining in the equipment has sufficient space to be decomposed to a 
safe level when the cabinet door is opened

9.  When opening the equipment for ozone disinfection, make sure that the equipment is in a well 

ventilated environment. If the equipment cannot be ensured to be in a well-ventilated environment, 
only open the cabinet door at least 30 minutes after an ozone disinfection session has finished

10. Ozone is unstable, breaks down rapidly at high temperatures, slowly breaks down to (oxygen) at room 

Summary of Contents for ULTIMATE UVP101R

Page 1: ...μW cm REV ODS Reverse Obstacle Detection System 2cm Sensor distance 7 4V 2600 mAh Li ion UV 3 3 5h O3 15 16h Input Output 5V 2A Work light specifications Center box Irradiance 240μW cm Intelligent UV OZONE Disinfection Box ULTIMATE UVP101R UVC Light germicidal system intends for use in general purpose ...

Page 2: ...ill start automatically If detecting the distance between the light source of disinfection light head and the surface of articles to be disinfected exceeds 2cm it will automatically stop the disinfection work and reach the safe energy efficient effects In case of disinfecting the surface of articles by independently hand held using it is usually able to kill 99 9 bacteria and virus on the surface ...

Page 3: ...tton during the disinfection will not be effective 10 It will automatically stop the ozone work in the last 10 minutes of preset time in the course of ozone disinfection and activate the ultraviolet automatically to perform 10 minute ozonolysis 11 If the battery level is lower than 20 and the battery level displays in red it is required to charge as soon as possible to avoid that the remaining bat...

Page 4: ...one disinfection As for the ordinary article disinfection it is suggested to disinfect for 60 minutes As for the professional article disinfection it is suggested to appropriately extend the disinfection time SAFETY WARNING 1 Please read and understand this user manual before use to ensure that the product is safely and properly used 2 Our Company shall not be liable for product damage and other i...

Page 5: ...ing to the FDA Although ozone has been reported to have adverse physiological effects on the central nervous system heart and vision its main physiological effect is to stimulate the mucous membranes Inhalation of ozone causes enough irritation to the lungs leading to pulmonary edema The onset of pulmonary edema is usually delayed by several hours after exposure As the hazards of ozone are widely ...

Page 6: ...eakage value is found to have exceeded the above standard the equipment must be immediately stopped To guarantee the disinfect effect of UVC 1 Whether UV light can effective disinfect depends on the amount of exposure received by the disinfection object which depends on the radiation power of the UV light source the distance of the disinfection object from the UV light source and the duration of t...

Page 7: ...es at a time using ozone concentrations of 35PPM 4 After 10 tests of six different leather material colors samples the results show color fading and hardening of the material especially the brighter samples whose fading was more pronounced 5 The same conditions were tested on stainless steel aluminum gold plated PIN needles silicone cotton pads cotton and ABS plastics and no significant decomposit...

Page 8: ...structions WARNING UV C emitted from this product Avoid eye and skin exposure to unshielded product Follow installation instructions and user manual www uvpluss com AEC Lighting Solutions Co Ltd Add 2548 Bao an Highway Jiading District Shanghai 201801 China Tel 400 083 8757 www aeclight reel com ...

Reviews:

Related manuals for ULTIMATE UVP101R