background image

        

SAFETY WARNING:

1.   Please read and understand this user manual before use, to ensure that the product is safely and 

properly used

2.  Our Company shall not be liable for product damage and other injuries caused by improper use or 

failure to follow this User Manual.

3.  Strictly forbid any children 0-12 years old to use this product. Users should carefully select places 

without children before use and ensure that children do not touch the product.

4.  Avoid the risk of electric shock during use.
5.  The use of this product in gas, flammable and explosive substances, and heat source environments is 

prohibited. 

6.  Don’t use wet hands in operating the product. Please keep the operating environment dry
7.  Do not remove, repair and alter the product by oneself. Repairs and battery replacements can only be 

carried out by authorized service providers and manufacturers, and repair and replacement of batteries 
by authorized service providers and personnel other than manufacturers may result in injury. Replacing 
the battery with the wrong model is a risk of explosion

8.  Use the product only at specified voltages and frequencies
9.  UV Light Hazard. Harmful to bare skin and eyes. Can cause temporary or permanent loss of vision. 

Never look at the bulbs while illuminated. Any exposed skin must not be exposed to UV light

        

CAUTION:

UVC-Equipment Damage Hazard.
1.   Ultraviolet light can cause color shift or structural degradation of plastic materials
2.  Ultraviolet light can cause color shift or structural degradation of resin materials
3.  Ultraviolet light can cause color shift or structural degradation of leatherwear
4.  Ultraviolet light can cause color shift or structural degradation of organic compounds materials

OZONE-Equipment Damage Hazard.
1.   OZONE can cause color shift or structural degradation of plastic materials
2.  OZONE can cause color shift or structural degradation of resin materials
3.  OZONE can cause color shift or structural degradation of leatherwear
4.  OZONE can cause color shift or structural degradation of organic compounds materials
5.  High concentrations of ozone for a long time can cause electronic products function damage

     bar will automatically switch off
4.  During the fixed-mode usage, the ozone disinfection will automatically stop after working for 60 

minutes, and automatically start the ultraviolet UVC to perform the ozonolysis for 10 minutes.

5.  If  “         ” on the screen disappears and the time displays the green number 0, the disinfection work is 

completed. It will switch off after 30 seconds if not performing any operation for the energy 
conservation and environment protection.

6.  If the battery level is lower than 20% and the battery is displayed in red “          ” , it is required to 

charge as soon as possible to avoid that the remaining battery power is insufficient to finish one 
complete disinfection.

7.  Long press the fixed-mode switch “       ” during the disinfection to shut down.
8.  During the fixed-mode using, the disinfection bar has the memory function. After starting each time, 

Summary of Contents for UVP201R

Page 1: ... ULTIMATE Center Irradiance 13500μW cm Sensor angle 80 Sensor distance 3m REV ODS Reverse Obstacle Detection System 2cm Sensor distance HBS Human body sensing system 7 3V 4000 mAh Li ion UV 2 5 3h O3 9 10h Input Output 5V 2A Work light specifications In Bag UVC Light germicidal system intends for use in general purpose ...

Page 2: ...y independently hand held using it is usually able to kill 98 56 99 99 bacteria and virus on the surface or articles within 3 seconds During the fixed mode using ozone disinfection has two steps weak ozone and strong ozone Weak ozone step is designed to eliminate odor and formaldehyde in non confined space e g shoe cabinet wardrobe Strong ozone step is applicable to the disinfection in confined sp...

Page 3: ...hing it will automatically shut down after 30 seconds saving energy and protecting the environment if you short press or long press the handheld mode switch you can also shut down the light II Fixed Usage of Disinfection Bar Available to select the ULTRAVIOLET mode or OZONE mode for disinfection 1 Short press the switch of fixed mode to start up Meanwhile the intelligent HBS system will automatica...

Page 4: ...ctural degradation of plastic materials 2 Ultraviolet light can cause color shift or structural degradation of resin materials 3 Ultraviolet light can cause color shift or structural degradation of leatherwear 4 Ultraviolet light can cause color shift or structural degradation of organic compounds materials OZONE Equipment Damage Hazard 1 OZONE can cause color shift or structural degradation of pl...

Page 5: ... poisonous range The odor of ozone is not a reliable warning indicator due to the possibility of olfactory fatigue 9 Long term occupied enclosed spaces such as houses apartments hospitals and offices should have ozone volumes below 0 1mg m 0 05PPM The ozone concentration in the workplace i e occupational exposure limit is 0 1PPM 10 The amount of space used by the equipment used to place and use th...

Page 6: ...d object it is recommended that In order to achieve the radiation dose of 10 000 μW cm to meet the general needs of daily use the exposure time should be at least above 1 4 seconds In order to achieve the radiation dose of 100 000 μW cm to meet the needs of the professional environment the exposure time should be at least above 500 seconds To guarantee the ozone disinfect effect 1 Ozone can kill b...

Page 7: ...ABS plastics and no significant decomposition was found 6 It is recommended to avoid ozone disinfection of brightly colored leather silk and other items Some highly aged items such as natural rubber are also recommended to not undergo ozone disinfection Since ozone has an oxidative effect on most metals users should not use ozone disinfection on electronic products to avoid ozone damage to devices...

Page 8: ...structions WARNING UV C emitted from this product Avoid eye and skin exposure to unshielded product Follow installation instructions and user manual www uvpluss com AEC Lighting Solutions Co Ltd Add 2548 Bao an Highway Jiading District Shanghai 201801 China Tel 400 083 8757 www aeclight reel com ...

Reviews:

Related manuals for UVP201R