1.   Short press “           ” to start the machine. If not performing any operation after starting the machine, it 

will automatically switch off after 30 seconds for the energy conservation and environment protection.

2.  Design of Hall Switch. If the screen displays “            ” , it indicates the disinfection case is closed; If the 

screen  displays , it indicates the disinfection case is not closed. 

3.  Short press “           ” to switch the disinfection mode: ultraviolet disinfection mode (screen will display 

“           ” ), ozone disinfection mode (screen will display “           ” ). 

4.  After selecting the disinfection mode, it is able to adjust the disinfection time by short pressing “+” or 

“-” button (screen will display the time): 

•    Under the ultraviolet disinfection mode, it is able to set up the disinfection time from 1 minute to 60 

minutes; Adjust the time by short pressing “+” or “-” button (It is able to accelerate the adjustment by 
long pressing for 1.5 seconds) 

•    Under the ozone disinfection mode, it is able to set up the disinfection time from 30 minute to 240 

minutes; Adjust the time by short pressing “+” or “-” button (It is able to accelerate the adjustment by 
long pressing for 1.5 seconds) 

5.  After adjusting the disinfection time, it is able to activate the disinfection work by long pressing “          ” 

for 1.5 seconds, and “         ” on the screen will flash. If not long pressing “           ” , it will automatically 
switch off after 30 seconds for energy conservation and environment protection. 

•    Under the ultraviolet disinfection mode, the white “          ” will change to purple “         ” 
•    Under the ozone disinfection mode, the white “          ” will change to blue “          ” 
6.  If the disinfection case is open during the disinfection, and the screen will display “          ” ,“         ” will 

disappear and the time will return to the preset time. 

7.  Long press “          ” during the disinfection to switch off the machine. 
8.  Short press “          ” , “+” button and “-” button during the disinfection will not be effective. 
9.  It will automatically stop the ozone work in the last 10 minutes of preset time in the course of ozone 

disinfection, and activate the ultraviolet automatically to perform the 10-minute ozonolysis.

10. If “         ” on the screen disappears and the time displays the green number 0, it indicates the 

disinfection work is completed.

11.  If the battery level is lower than 20% and the battery level displays in red “            ” , it is required to 

charge as soon as possible to avoid that the remaining battery power is insufficient to finish one 
complete disinfection.

12. After the disinfection work is completed, it will automatically switch off after 30 seconds if not 

performing any operation for the energy conservation and environment protection. 

13. The disinfection case has the memory function: After starting the machine each time, the screen will 

display the mode and time of disinfection work for the last time.

Operation Instruction:

UVC

Summary of Contents for UVP401R

Page 1: ...V OZONE Sterilization Case PLUS UVC LED 120 275nm UVC Work light specifications Center box Irradiance 300μW cm Input MAX 25W Output 3 4h 4 2 kg IP65 60mg m 27ppm 10 95V 8000mAh Li ion UV 4 5h O3 15h 12 6V 4 3A 365x297x168mm ...

Page 2: ...amage of ultraviolet or ozone to human body With the intelligent button operation interface it is able to independently select and adjust the disinfection mode and disinfection time Color LCD screen can display the information e g disinfection mode disinfection time and state of charge etc in real time The external case is under the German Quality with strong corrosion resistance and shock resista...

Page 3: ...t long pressing it will automatically switch off after 30 seconds for energy conservation and environment protection Under the ultraviolet disinfection mode the white will change to purple Under the ozone disinfection mode the white will change to blue 6 If the disinfection case is open during the disinfection and the screen will display will disappear and the time will return to the preset time 7...

Page 4: ...t children before use and ensure that children do not touch the product 4 Avoid the risk of electric shock during use 5 The use of this product in gas flammable and explosive substances and heat source environments is prohibited 6 Don t use wet hands in operating the product Please keep the operating environment dry 7 Do not remove repair and alter the product by oneself Repairs and battery replac...

Page 5: ... pay full attention to the use of ozone 6 At Ozone concentrations of 0 02PPM 0 04mg m ozone can be smelled by people with acute olfactory senses at 0 15PPM 0 32mg m ozone can be smelled by the general population at 1 10PPM 2 14 21 4mg m ozone has reached the stimulus range and can be clearly smelled at 10PPM 21 4mg m ozone has reached the toxic range or more poisonous range The odor of ozone is no...

Page 6: ...ght source the distance of the disinfection object from the UV light source and the duration of the exposure to UV light 2 When killing common microorganisms the irradiated dose should reach 10 000 μW cm 100 000 μ W cm is the recommended dose to kill bacterial spores The radiation dose should not be less than 100 000 μW cm when the target microorganism for disinfection is unknown 3 According to th...

Page 7: ...leather material colors samples the results show color fading and hardening of the material especially the brighter samples whose fading was more pronounced 5 The same conditions were tested on stainless steel aluminum gold plated PIN needles silicone cotton pads cotton and ABS plastics and no significant decomposition was found 6 It is recommended to avoid ozone disinfection of brightly colored l...

Page 8: ...structions WARNING UV C emitted from this product Avoid eye and skin exposure to unshielded product Follow installation instructions and user manual www uvpluss com AEC Lighting Solutions Co Ltd Add 2548 Bao an Highway Jiading District Shanghai 201801 China Tel 400 083 8757 www aeclight reel com ...

Reviews:

Related manuals for UVP401R