 Can control the sterilization solution output through dry fog, such that the dry fog particle size is 

accurate and consistent, reducing the risk at condensation and wetting, guaranteeing the best 
disinfection effect at complex area

 Able to effectively cover all spaces in the cleaning site

 Delayed start time switch function

 Sterilization area parameters memory function

 Built-in calculation software

 Sturdy structure, easy maintenance

 One single equipment can disinfect 20-500m3 space

 The whole process takes 2-4 hours, greatly shortening disinfection duration

 Replaced methanol, and can achieve Log6 sterilization rate

 GMR, FDA and EP recommend sterilization method in cleaning area

4. Product characteristics

5. Equipment structure

1.  Disinfectant bottle (Disinfectant is purchased separately)
2. Nozzle
3. Lock buckle
4. Nozzle base
5. Handle
6. Touch screen
7. Housing
8. Filter switch socket

Summary of Contents for UVP801C

Page 1: ...roxide Disinfector UVP801C 484x270x314mm 7 1kg 80m s 500m Log6 Work light specifications 16ml min Sterilization effect Sterilization volume Sterilization speed 10 µm Hydrogen peroxide solution 22000rps Max 1200W Output 1 ...

Page 2: ...est condition Laser particle size analyzer One hour test 18 points space disinfection test Thank you for using our product our company will provide you with the best service and our Dry fog hydrogen peroxide disinfector is easy to use safe and reliable This manual contains detailed information on how to use the sprayer equipment management personnel and operators must fully read this manual prior ...

Page 3: ...ea parameters memory function Built in calculation software Sturdy structure easy maintenance One single equipment can disinfect 20 500m3 space The whole process takes 2 4 hours greatly shortening disinfection duration Replaced methanol and can achieve Log6 sterilization rate GMR FDA and EP recommend sterilization method in cleaning area 4 Product characteristics 5 Equipment structure 1 Disinfecta...

Page 4: ... the event of malfunction or breakdown grounding provides a path of least resistance for electric current to reduce the risk of electric shock This appliance is equipped with a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances DANGER improper...

Page 5: ... the like extending from the adaptor must be connected to a permanent ground such as a properly grounded outlet box cover Whenever the adaptor is used it must be held in place by a metal screw Turning on the power switch will enter into below user interface 6 Parameters setting User is required to set the room size the residual dose volume of the disinfectant then click Start Start Delay countdown...

Page 6: ...me settings according to the actual sterilization area size and equipment location Enter actual volume of the sterilization area into the Room Volume Delay time can be set according to the user s needs After each setting is set the interface will automatically display the estimated dosage total added amount sterilization time and running time Move the equipment in place then open any inner doors o...

Page 7: ...to achieve the desired sterilization effect How much additional time is directly proportional to the reduced solution percentage ie if 3 solution is used the equipment must be set to spray twice the needed amount which also means twice the amount of time compared to 6 solution Dwell time and residue removal duration is not affected User safety The user use 3M8514 welding protection mask or equal g...

Page 8: ...e mask or similar grade protective mask When repairing the equipment in addition to wearing the above protective mask the equipment should be kept in a well ventilated environment Drop off the residual disinfectant after each time use finished use the purified water to atomizing trial wash pipeline and spraying head under the allowed condition for maintenance purpose 9 Daily maintenance Do not sta...