11. After sales service

10. Notice

 Ensure that the environment is kept relatively clean and, in as much as possible, a low dust 

environment

 After each use, the remaining disinfectant liquid should be disposed of, and if conditions permit, 

use purified water to clean the tubes and nozzles via dry fog spraying

 Wipe the equipment surface clean with purified water after each use

 Avoid using any sharp objects to touch against or rub on the touch screen, to avoid scratching the 

screen

 If any disinfectant liquid flows onto the surface or into the interior of the equipment during use, 

clean it promptly.

 Store equipment in a dry and well ventilated place

 In order to ensure the safety of the user, this product has set up a full safety device. Daily spot 

checks are necessary to ensure the safe use of equipment. Check as required by the specification 
and stop using the device immediately if the problem is identified. In the use of disinfection, or 
equipment regular inspection, the use of 3M8514 welded protective mask (or similar grade 
protective mask). When repairing the equipment, in addition to wearing the above protective mask, 
the equipment should be kept in a well ventilated environment

 Drop off the residual disinfectant after each time use finished, use the purified water to atomizing 

trial wash pipeline and spraying head under the allowed condition for maintenance purpose

9. Daily maintenance

 Do not stay or enter sterilization room when equipment are running

 Vacate all personnel from the area to be sprayed to avoid causing illness or injury

 Ensure that appropriate personal protective gear is worn/used when operating the sterilizer

 Do not use excessive force against the touch screen, do not touch the screen with sharp objects, 

and avoid scratching the surface of the screen.

 One year warranty, lifetime maintenance

 Provide professional supplies, including high-strength composite nozzles and disinfectant bottle

 Each customer is given its own account, and their information

 Regular software updates

 Professional training in hydrogen peroxide disinfection technology

V1/HJ

AEC Lighting Solutions Co., Ltd

Add.: 2548 Bao’an Highway, Jiading District, Shanghai 201801, China 

www.aeclight-reel.com

www.uvpluss.com

Summary of Contents for UVP801C

Page 1: ...roxide Disinfector UVP801C 484x270x314mm 7 1kg 80m s 500m Log6 Work light specifications 16ml min Sterilization effect Sterilization volume Sterilization speed 10 µm Hydrogen peroxide solution 22000rps Max 1200W Output 1 ...

Page 2: ...est condition Laser particle size analyzer One hour test 18 points space disinfection test Thank you for using our product our company will provide you with the best service and our Dry fog hydrogen peroxide disinfector is easy to use safe and reliable This manual contains detailed information on how to use the sprayer equipment management personnel and operators must fully read this manual prior ...

Page 3: ...ea parameters memory function Built in calculation software Sturdy structure easy maintenance One single equipment can disinfect 20 500m3 space The whole process takes 2 4 hours greatly shortening disinfection duration Replaced methanol and can achieve Log6 sterilization rate GMR FDA and EP recommend sterilization method in cleaning area 4 Product characteristics 5 Equipment structure 1 Disinfecta...

Page 4: ... the event of malfunction or breakdown grounding provides a path of least resistance for electric current to reduce the risk of electric shock This appliance is equipped with a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances DANGER improper...

Page 5: ... the like extending from the adaptor must be connected to a permanent ground such as a properly grounded outlet box cover Whenever the adaptor is used it must be held in place by a metal screw Turning on the power switch will enter into below user interface 6 Parameters setting User is required to set the room size the residual dose volume of the disinfectant then click Start Start Delay countdown...

Page 6: ...me settings according to the actual sterilization area size and equipment location Enter actual volume of the sterilization area into the Room Volume Delay time can be set according to the user s needs After each setting is set the interface will automatically display the estimated dosage total added amount sterilization time and running time Move the equipment in place then open any inner doors o...

Page 7: ...to achieve the desired sterilization effect How much additional time is directly proportional to the reduced solution percentage ie if 3 solution is used the equipment must be set to spray twice the needed amount which also means twice the amount of time compared to 6 solution Dwell time and residue removal duration is not affected User safety The user use 3M8514 welding protection mask or equal g...

Page 8: ...e mask or similar grade protective mask When repairing the equipment in addition to wearing the above protective mask the equipment should be kept in a well ventilated environment Drop off the residual disinfectant after each time use finished use the purified water to atomizing trial wash pipeline and spraying head under the allowed condition for maintenance purpose 9 Daily maintenance Do not sta...

Reviews:

Related manuals for UVP801C