26
3. Diving with Aladin 2G
SCUBAPRO ALADIN 2G
3.4.8 Oxygen toxicity (CNS O
2
%)
CNS O
2
%
Oxygen toxicity
Aladin 2G calculates oxygen toxicity based
on depth, time and the gas mixture and
displays it in the location of the ascent rate.
The toxicity is expressed in 1% increments
of a maximum tolerated value (O
2
clock).
The symbol “CNS O
2
” is displayed together
with the percentage.
CNS O
2
%
DEPTH
NO STOP
DIVE TIME
4s
WARNING
An audible attention signal goes off if oxygen
toxicity reaches 75%. The symbol “CNS O
2
”
flashes.
Ascend to shallower depth to decrease oxygen
loading and consider terminating the dive.
CNS O
2
%
DEPTH
NO STOP
DIVE TIME
WARNING
When oxygen toxicity reaches 100%, an
audible alarm goes off every 4 seconds.
“CNS O
2
” and the percentage value flash.
Danger of oxygen toxicity!
Start procedure for terminating the dive.
)
NOTE:
• During an ascent and if the CNS O
2
%
value does not increase anymore
(due to a lower partial pressure
of oxygen), the audible warning is
suppressed.
• During the ascent, the display of the
oxygen toxicity is replaced by the
ascent rate. If the ascent is stopped,
the display changes back to the
indication of the CNS value.
• Aladin 2G will display CNS O
2
%
values exceeding 199% with 199%.
3.4.9 Nitrogen loading bar graph
The nitrogen loading bar gives a
graphical representation of how close to
decompression you are. As you absorb
nitrogen during the dive, more and more
segments of the bar will light up. Depending
on your depth, the segments can light up
more or less rapidly.
1-3 segments (green area):
you are safely within the no-stop range
Summary of Contents for Aladin 2G