Setpoint 2 is dedicated to Oxygen tank and
the setting procedure is as with Setpoint 1.
Bailout is an open circuit gas and it is set
as the Gas 1.
4.2.2
Enabling the CCR mode
Refer to chapter 5.8.6 to learn more about
diving with CCR mode.
By pressing the SEL button in this display
the CCR mode on or off starts blinking and
can be selected by pressing the +/UP or
-/DOWN buttons. By pressing the SEL
button you will confirm the setting.
4.2.3
Nitrox reset time
If you are generally diving with air and want
to return to this setting after the occasional
nitrox dive, you can preset a default time
when your MANTIS will reset back to air.
By pressing the SEL button the time shown
on the bottom row starts blinking. The time
can be selected from 1 hour up to 48 hours
or the nitrox reset time can be disabled by
pressing the +/UP or -/DOWN buttons. Gas
reset time is disabled when - - h is shown.
F
NOTE: The Nitrox reset disables the
Gas d and Gas 2.
4.2.4
Heart rate limits
By pressing the SEL in this menu the
maximum heart rate (HI) value starts
blinking and by pr/UP or -/DOWN
you may select the limit from 140 up to 220.
By pressing the SEL button the base heart
rate (LO) starts blinking and by pressing
+/UP or -/DOWN you may select the limit
from 60 up to 120. A base heart rate should
be selected so that it represents normal
heart rate during a typical dive.