Syndrome Rated capacity cannot be reached
Check
Is the
TARE INDICATOR
on?
Action:
Turn the scale off. Remove all loads
from platter and turn on again.
Check
Is there anything obstructing the
platter?
Action
Remove all obstacles.
Syndrome Weighing result is not accurate
Check
Is the scale placed in a level
condition?
Action
Adjust the adjustable feet to a level
condition.
Check
Is the scale affected by airflow,
vibration or RFI?
Action:
Place the scale away from all
disturbances.
Check
Is the scale calibrated correctly?
Action
Contact your dealer.
Check
Is the correct weight unit employed?
Action
Refer to
4.2.1
and
5.3
for weight
unit setting and usage.
Syndrome Scale displays
00000
Check
Is the scale overloaded?
Action
Remove some loads from platter.
Syndrome Scale displays
00000
Check
Is the stainless steel platter cover
placed on the platter?
Action
Place the stainless steel platter
cover onto the platter.