Minimum Weight Required for
Model No.
Mode 00
Mode 01
GW-1500
3g
4g
GW-3000
6g
8g
GW-7500
15g
20g
GW-15K
30g
40g
GW-30K
60g
80g
Appendix B
RS232 Data Format of Function 20
Format 00 (Default)
S T ,
1 0 0 . 0 5
g
CR LF
Position code
1
2
3 4 5 6 7 8 9 10 11 12 13
Format 01
U S , -
1 0 . 0 5
g , G CR LF
Position Code
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Format 02
+
1
0
0
.
0
5
CR
LF
Position Code
3 4 5 6 7 8 9 10
Position Code Definition:
1
2
=Weight Status:
ST=Stable
RS=Not stable
3
= Polarity of value (Plus or Minus)
+ or blank = positive value
-
= Negative value
4
5
6
7
8
9
10
=Value of weight, pieces or percentage
12 13
=Unit
kg = kilogram
g = gram
pc = pieces
% = percentage
14
= Weight check result
H = Weight detected over upper limit.
G = Weight detected falls within upper and
lower limit.
L = Weight detected below lower limit.
Appendix C
Printout Format of Function 21
Format 00 (Default)