Page: 10
DISPLAY INDICATORS
19- LOW-BATTERY INDICATOR
***This sign appears when the battery is low.
20- M+ INDICATOR
An arrow on this sign indicates the accumulation function is in
use.
21- MR INDICATOR
An arrow on this sign indicates that the accumulation data is
currently shown on the display.
22- WEIGHING UNITS INDICATOR
This indicator shows the current weighing unit employed.
***Charge the scale immediately when the LOW-BATTERY sign
appears. Failure to do so can shorten the life of the rechargeable
battery.
Page: 11
INTERNAL FUNCTIONS
To access the internal functions:
<1> Press and hold TARE, then press <ON/ZERO>
<2> Display will show “F0”
<3> Press TARE until the desired Function is displayed
<4> Press MODE/RANGE to enter function
<5> Press MODE/RANGE to make selection
<6> Press TARE to confirm selection
<7> Press ON/ZERO key to return to weighing mode
F0
Set the Auto Zero Tracking range (Zero_X, can select how
many divisions of e to Auto Zero)
Within the setting range, the weight is forced to be zero.
F1
Span Value display
F2
Software version display and full display test
F3
Displays default weighing units used and disable/enable
different weighing units shown when pressing MODE in
normal weighing mode
F4
Enable/disable Auto Power Off
F5
RS-232 Interface Setting (Baud Rate, Parity Setting)
F6
Enable/disable Digital Filter (FiLt_0 ~ FiLt_5)
F7
RS-232 transmission mode (P-Out, Conti, Auto)
F8
Tare mode (n_tArE, S_tArE)