RONDA
®
520
11
V. BRØNDUM A/S
The manufacturer, or an instructed person, must perform a technical inspection at least annually,
consisting of, for example, inspection of filters for damage, air tightness of the appliance and proper
function of the control mechanism. On class H appliances the appliance filtration efficiency should be
tested at least annually, or more often, according to national requirements. The test method that may
be used for the verification of the appliance filtration efficiency is given in AA.22.201.2. If the test is not
passed, it must be repeated with a new essential filter.
When carrying out service or repair operations, all contaminated items, which cannot be satisfactorily
cleaned, are to be disposed of. Such items shall be disposed of in impervious bags in accordance with
any current regulation of the disposal of such waste.
The upper part of the motor top is a non-dust proof compartment, and when cleaning, the covers of
this compartment are removed by loosening the screws fixing the covers.
IMPORTANT! The vacuum cleaner must not be started with covers removed.
IMPORTANT! The motor top must not be covered when the vacuum cleaner is in use.
WARNING
: If foam or liquid emerges from the machine, power must be cut off immediately. If the float valve
closes of when vacuuming liquid, because the container is full, the motors of the machine must be immediately
turned off.
Summary of Contents for RONDA 520
Page 2: ...RONDA 520 2 V BR NDUM A S...