background image

backlight on the display panel. Press the "Enter" key to enter the setting. Press

the "UP" or "DOWN" key to switch the LCD backlight, select "Yes" "Means that

the LCD backlight is always on and will not be turned off. Selecting "NO"

means it will be turned off after 20 seconds without any key operation until it is

turned on again when there is a key operation. After selecting the settings,

press "Enter" to save and exit.

Invert Word:

Inverted font

English/Chinese: Chinese to English conversion

LCD Backlight

on LCD Backlight on setting

此选项是对显示板液晶字体倒向、中英文显示和背光灯进行设置,按

“Enter”

键可

进入设置,液晶背光灯按

“UP”

键或者

“DOWN”

键可进行开关选择,选择

“Yes”

示液晶背光灯一直长亮

,

不关断,选择

“NO”

表示没有按键操作连续

20

秒后关断

,

直到有按键操作时重新开启。选好设置后按

“Enter”

保存退出。

Invert Word

字体倒向

English/Chinese:

中英文转换

LCD Backlight on

液晶背光灯开启设置

5.Manual Set(

手动模式设置

)

This option is to set the scene parameters of the lamp body, press the "Enter"

key to enter the save, and online operation can be carried out, provided that

the lamp body's operating mode (Run Mode) is set to manul, that is, the

manual mode is valid. , The next startup can restore the previous startup state.

PAN:

X axis position

PANMICO: X-axis fine adjustment

TILT:

Y axis position

TILTMICO: Y-axis fine adjustment

ZOOM:

focus position

DIM:

Total dimming

STROBE:

Strobe

DIM_R:

Red dimming

DIM_G:

Green dimming

DIM_B:

Blue dimming

DIM_W:

White dimming

此选项是对灯体场景参数进行设置,按

“Enter”

键可进入保存,可进行联机运行,

前提灯体的工作模式(

Run Mode

)要设置为

manul,

也就是手动模式才有效,断

电后,下一次开机可恢复前一次开机状态。

PAN

X

轴位置

PANMICO

X

轴微调

TILT

Y

轴位置

TILTMICO

Y

轴微调

ZOOM

调焦位置

DIM

总调光

STROBE

频闪

DIM_R

红色调光

Summary of Contents for BWZ3715

Page 1: ...Beam Wash Zoom Moving Head 3715 37 15W LED BWZ3715 User Manual KEEP THIS MANUAL FOR FUTURE NEEDS...

Page 2: ...The fixture is designed and manufactured strictly following CE standards complying with international standard DMX512 protocol It s available independently controlled and linkable with each other for...

Page 3: ...sure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual If the device has been exposed to temperature changes due...

Page 4: ...use or before cleaning it Only handle the power cord by the plug Never pull out the plug by tugging the power cord During initial start up some smoke or smell may arise This is a normal process and d...

Page 5: ...t And don t lay any power cables on the floor Or it might cause electronic shock to the people Make sure the installation place is in good safety condition before installing the fixture Make sure to p...

Page 6: ...ounting removing or servicing the fixture from a periodic safety inspection of all installation material and the fixture If you lack these qualifications do not attempt the installation yourself Impro...

Page 7: ...he fixture using on of the safety cable rigging point integrated in the base assembly M10 5 DMX 512 control connections Connect the provided XLR cable to the female 3 pin XLR output of your controller...

Page 8: ...s recommended to use a DMX terminator This helps in preventing corruption of the digital control signal by electrical noise The DMX terminator is simply an XLR plug with a 120 resistor connected betwe...

Page 9: ...mperature XY axis fine tuning and lamp white balance parameters can be set Adjustable color temperature 10000 2500K This lamp has a circle control function When in 36 channel mode it can be divided in...

Page 10: ...ABS XY 10000 2500K 36 48 1 6 RGBW 7 Dimensions...

Page 11: ...2 Slow and Fast in turn Sound and manual after selecting the working mode press Enter to save and exit DMX512 Console operation mode Slow Slow self propelled mode Fast Fast self propelled mode Sound A...

Page 12: ...on setting Enter UP DOWN Yes NO 20 Enter Invert Word English Chinese LCD Backlight on 5 Manual Set This option is to set the scene parameters of the lamp body press the Enter key to enter the save an...

Page 13: ...lay Normal normal Wrong error Default Settings restore factory settings Code Settings Password channel In the password channel the user needs to enter the password to view and set the XY fine tuning a...

Page 14: ...54 From slow to fast 1HZ 25HZ 155 204 Random strobe 205 255 Lightning strobe 9 R 0 255 Red from dark to bright 10 G 0 255 Green from dark to light t 11 B 0 255 Blue from dark to light 12 W 0 255 White...

Page 15: ...in static pattern effect7 80 89 Built in static pattern effect8 90 99 Built in static pattern effect9 100 109 Built in static pattern effect10 110 119 Built in static pattern effect11 120 129 Built in...

Page 16: ...ntrol 24 Reset 0 239 No function 240 250 The lamp is reset valid for 3s 251 255 No function 24 DMX 1 X 0 255 0 540 2 X 0 255 16bit 3 Y 0 255 0 270 4 Y 0 255 16bit 5 XY 0 255 6 0 255 7 0 255 8 0 9 10 1...

Page 17: ...25 239 240 255 15 0 9 10 19 1 20 29 2 30 39 3 40 49 4 50 59 5 60 69 6 70 79 7 80 89 8 90 99 9 100 109 10 110 119 11 120 129 12 130 139 13 140 149 14 150 159 15 160 169 16 170 179 17 180 189 18 190 199...

Page 18: ...255 Lightning strobe 9 R 1 0 255 R from dark to bright 10 G 1 0 255 G from dark to bright 11 B 1 0 255 B from dark to bright 12 W 1 0 255 W from dark to bright 13 R 2 0 255 R from dark to bright 14 G...

Page 19: ...ilt in color effects17 180 189 Built in color effects18 190 199 Built in color effects19 200 209 Built in color effects20 210 224 Color jump effect 225 239 Color pulse effect 240 255 Color gradient ef...

Page 20: ...W 0 255 27 28 channel backlight 33 Effect direction adjustment 0 127 Positive direction of dynamic pattern 128 255 Dynamic pattern reverse direction 34 Effect speed 0 255 Speed from fast to slow 35 Ma...

Page 21: ...55 4 23 4 0 255 4 24 4 0 255 4 25 COT 0 9 10 255 10000K 2500K 26 0 9 10 19 1 20 29 2 30 39 3 40 49 4 50 59 5 60 69 6 70 79 7 80 89 8 90 99 9 100 109 10 110 119 11 120 129 12 130 139 13 140 149 14 150...

Page 22: ...9 20 210 255 28 0 9 10 255 12 20 29 0 255 27 28 30 0 255 27 28 31 0 255 27 28 32 0 255 27 28 33 0 127 128 255 34 0 255 35 0 9 10 99 1 100 199 2 200 255 36 0 239 240 250 3s 251 255 48CH 48CH Function D...

Page 23: ...2500K 38 Color effect 0 9 No function 10 19 Built in color effects1 20 29 Built in color effects2 30 39 Built in color effects3 40 49 Built in color effects4 50 59 Built in color effects5 60 69 Built...

Page 24: ...ect16 170 179 Static pattern effect17 180 189 Static pattern effect18 190 199 Static pattern effect19 200 209 Static pattern effect20 210 255 Static pattern effect 40 dynamic effect 0 9 No function 10...

Page 25: ...5 8 0 9 10 154 1HZ 25HZ 155 204 205 255 9 1 0 255 1 10 1 0 255 1 11 1 0 255 1 12 1 0 255 1 33 7 0 255 7 34 7 0 255 7 35 7 0 255 7 36 7 0 255 7 37 COT 0 9 10 255 10000K 2500K 38 0 9 10 19 1 20 29 2 30...

Page 26: ...20 29 2 30 39 3 40 49 4 50 59 5 60 69 6 70 79 7 80 89 8 90 99 9 100 109 10 110 119 11 120 129 12 130 139 13 140 149 14 150 159 15 160 169 16 170 179 17 180 189 18 190 199 19 200 209 20 210 255 40 0 9...

Page 27: ...killed installers and any safety issues must be eliminated In order to keep the lamp in good condition and prolong its service life we recommend cleaning the lamp regularly 1 Clean the inner and outer...

Page 28: ......

Reviews: