background image

temperature.

This device falls under protection-class I. Therefore it is essential that the

device be earthed.

The electric connection must carry out by qualified person.

The device shall only be used with rate voltage and frequency.

Make sure that the available voltage is not higher than stated at the end of this

manual.

Make sure the power cord is never crimped or damaged by sharp edges. If this

would be the case, replacement of the cable must be done by an authorized

dealer.

Always disconnect from the mains, when the device is not in use or before

cleaning it. Only handle the power cord by the plug. Never pull out the plug by

tugging the power cord.

During initial start-up some smoke or smell may arise. This is a normal process

and does not necessarily mean that the device is defective, it should decrease

gradually.

Please don't project the beam onto combustible substances.

Fixtures cannot be installed on combustible substances, keep more than 50cm

distance with wall for smooth air flow, so there should be no shelter for fans

and ventilation for heat radiation.

If the external flexible cable or cord of this luminaire is damaged, it shall

be exclusively replaced by the manufacturer or his service agent or a similar

qualified person in order to avoid a hazard.

2. 安全说明

该设备已经完好出厂。为了维持这种状态并确保安全操作,用户绝对有

必要遵守本用户手册中编写的安全说明和警告说明。

如果设备因环境变化而遭受温度变化,请勿立即开启设备。产生的冷凝

水可能会损坏设备。保持设备关闭,直到达到室温。 该设备属于

I

保护。因此,必须将设备接地。 电气连接必须由合格人员进行。 该设

备只能在额定电压和频率下使用。 确保可用电压不高于本手册末尾所

述的电压。 确保电源线不会被尖锐的边缘压接或损坏。在这种情况下,

必须由授权经销商更换电缆。 不使用设备时或清洁设备之前,请务必

断开电源

​ ​

。只能通过拔插来处理电源线。切勿通过拉扯电源线来拔

Summary of Contents for BWZ3715

Page 1: ...Beam Wash Zoom Moving Head 3715 37 15W LED BWZ3715 User Manual KEEP THIS MANUAL FOR FUTURE NEEDS...

Page 2: ...The fixture is designed and manufactured strictly following CE standards complying with international standard DMX512 protocol It s available independently controlled and linkable with each other for...

Page 3: ...sure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual If the device has been exposed to temperature changes due...

Page 4: ...use or before cleaning it Only handle the power cord by the plug Never pull out the plug by tugging the power cord During initial start up some smoke or smell may arise This is a normal process and d...

Page 5: ...t And don t lay any power cables on the floor Or it might cause electronic shock to the people Make sure the installation place is in good safety condition before installing the fixture Make sure to p...

Page 6: ...ounting removing or servicing the fixture from a periodic safety inspection of all installation material and the fixture If you lack these qualifications do not attempt the installation yourself Impro...

Page 7: ...he fixture using on of the safety cable rigging point integrated in the base assembly M10 5 DMX 512 control connections Connect the provided XLR cable to the female 3 pin XLR output of your controller...

Page 8: ...s recommended to use a DMX terminator This helps in preventing corruption of the digital control signal by electrical noise The DMX terminator is simply an XLR plug with a 120 resistor connected betwe...

Page 9: ...mperature XY axis fine tuning and lamp white balance parameters can be set Adjustable color temperature 10000 2500K This lamp has a circle control function When in 36 channel mode it can be divided in...

Page 10: ...ABS XY 10000 2500K 36 48 1 6 RGBW 7 Dimensions...

Page 11: ...2 Slow and Fast in turn Sound and manual after selecting the working mode press Enter to save and exit DMX512 Console operation mode Slow Slow self propelled mode Fast Fast self propelled mode Sound A...

Page 12: ...on setting Enter UP DOWN Yes NO 20 Enter Invert Word English Chinese LCD Backlight on 5 Manual Set This option is to set the scene parameters of the lamp body press the Enter key to enter the save an...

Page 13: ...lay Normal normal Wrong error Default Settings restore factory settings Code Settings Password channel In the password channel the user needs to enter the password to view and set the XY fine tuning a...

Page 14: ...54 From slow to fast 1HZ 25HZ 155 204 Random strobe 205 255 Lightning strobe 9 R 0 255 Red from dark to bright 10 G 0 255 Green from dark to light t 11 B 0 255 Blue from dark to light 12 W 0 255 White...

Page 15: ...in static pattern effect7 80 89 Built in static pattern effect8 90 99 Built in static pattern effect9 100 109 Built in static pattern effect10 110 119 Built in static pattern effect11 120 129 Built in...

Page 16: ...ntrol 24 Reset 0 239 No function 240 250 The lamp is reset valid for 3s 251 255 No function 24 DMX 1 X 0 255 0 540 2 X 0 255 16bit 3 Y 0 255 0 270 4 Y 0 255 16bit 5 XY 0 255 6 0 255 7 0 255 8 0 9 10 1...

Page 17: ...25 239 240 255 15 0 9 10 19 1 20 29 2 30 39 3 40 49 4 50 59 5 60 69 6 70 79 7 80 89 8 90 99 9 100 109 10 110 119 11 120 129 12 130 139 13 140 149 14 150 159 15 160 169 16 170 179 17 180 189 18 190 199...

Page 18: ...255 Lightning strobe 9 R 1 0 255 R from dark to bright 10 G 1 0 255 G from dark to bright 11 B 1 0 255 B from dark to bright 12 W 1 0 255 W from dark to bright 13 R 2 0 255 R from dark to bright 14 G...

Page 19: ...ilt in color effects17 180 189 Built in color effects18 190 199 Built in color effects19 200 209 Built in color effects20 210 224 Color jump effect 225 239 Color pulse effect 240 255 Color gradient ef...

Page 20: ...W 0 255 27 28 channel backlight 33 Effect direction adjustment 0 127 Positive direction of dynamic pattern 128 255 Dynamic pattern reverse direction 34 Effect speed 0 255 Speed from fast to slow 35 Ma...

Page 21: ...55 4 23 4 0 255 4 24 4 0 255 4 25 COT 0 9 10 255 10000K 2500K 26 0 9 10 19 1 20 29 2 30 39 3 40 49 4 50 59 5 60 69 6 70 79 7 80 89 8 90 99 9 100 109 10 110 119 11 120 129 12 130 139 13 140 149 14 150...

Page 22: ...9 20 210 255 28 0 9 10 255 12 20 29 0 255 27 28 30 0 255 27 28 31 0 255 27 28 32 0 255 27 28 33 0 127 128 255 34 0 255 35 0 9 10 99 1 100 199 2 200 255 36 0 239 240 250 3s 251 255 48CH 48CH Function D...

Page 23: ...2500K 38 Color effect 0 9 No function 10 19 Built in color effects1 20 29 Built in color effects2 30 39 Built in color effects3 40 49 Built in color effects4 50 59 Built in color effects5 60 69 Built...

Page 24: ...ect16 170 179 Static pattern effect17 180 189 Static pattern effect18 190 199 Static pattern effect19 200 209 Static pattern effect20 210 255 Static pattern effect 40 dynamic effect 0 9 No function 10...

Page 25: ...5 8 0 9 10 154 1HZ 25HZ 155 204 205 255 9 1 0 255 1 10 1 0 255 1 11 1 0 255 1 12 1 0 255 1 33 7 0 255 7 34 7 0 255 7 35 7 0 255 7 36 7 0 255 7 37 COT 0 9 10 255 10000K 2500K 38 0 9 10 19 1 20 29 2 30...

Page 26: ...20 29 2 30 39 3 40 49 4 50 59 5 60 69 6 70 79 7 80 89 8 90 99 9 100 109 10 110 119 11 120 129 12 130 139 13 140 149 14 150 159 15 160 169 16 170 179 17 180 189 18 190 199 19 200 209 20 210 255 40 0 9...

Page 27: ...killed installers and any safety issues must be eliminated In order to keep the lamp in good condition and prolong its service life we recommend cleaning the lamp regularly 1 Clean the inner and outer...

Page 28: ......

Reviews: