16
OEM TM-50 User’s Guide
The OEM TM-50 Controller
6174007.fm
The OEM TM-50 Controller
The OEM TM-50 Controller is used to set all
the parameters of the OEM TM-50’s operation
with the exception of the sealer temperature
controls and the take-up tension control.
The controller uses a simple menu-driven pro-
gram for changing the current settings and
running the machine. This program is dis-
played on the LCD screen and navigation of
the menus and data entry are performed using
the keypad to the left of the LCD screen.
The microprocessor stores all settings and the
current parts counter value in memory when
the machine is powered down and restores
them when it is powered up again.
Note
: Power off the OEM TM-50 Controller
before inserting or removing any cables or
cords from the ports on the back of the
controller. Failure to power off the control-
ler before making changes may result in
damage to the controller and the external
device.
Controller Operation
When the OEM TM-50 is powered up, the con-
troller will display an initial welcome screen
shown in Figure 2.3.
From this screen, the operator can choose to
begin running the machine immediately or to
review and change the machine settings. As
the screen indicates, pressing the LEFT
ARROW key on the keypad will select the
Setup Menu and pressing the RIGHT ARROW
key will select Run Mode.
Setup Menu
The Setup Menu consists of eight menu
options, seven of which are used to review
and change an aspect of the OEM TM-50’s
operation. These options include: count, pitch,
tape advance, speed, sealer dwell, tape jog,
and mode. The last option is used to enter
Run Mode after setup is complete and the
operator is ready to begin a run. The Menu will
appear as shown in Figure 2.4.
An option is selected by pressing the number
key on the keypad that is indicated by the
Setup Menu screen. Pressing the escape
(ESC) key will exit and return to the Setup
Menu. Data entry is performed by entering the
desired number with the keypad and pressing
the enter (ENT) key to enter it.
Figure 2.2
V-TEK TM50
SETUP RUN
Figure 2.3
1>COUNT 2>PITCH
3>ADVANCE 4>SPEED
5>DWELL 6>JOG
7>MODE 8>RUN
Figure 2.4
Summary of Contents for OEM TM-50 SMD
Page 2: ......
Page 4: ......
Page 10: ...Safety Warning Labels 61685113 fm vi ...
Page 28: ...16 OEM TM 50 User s Guide Machine Overview 61685225 fm ...
Page 43: ...6174007 fm Using the Vision Port Chapter 2 Controller 29 Vision Hookup Example Figure 2 33 ...
Page 74: ...60 OEM TM 50 User s Guide Electrical Connections 6174322 fm Figure 4 6 ...
Page 95: ...61004015 fm Appendix A Sensors A 1 Appendix A Sensors ...
Page 102: ...Service and Parts Contacts 61053915 fm Page 2 ...
Page 104: ......
Page 106: ...TM 50 OEM Sensors Spare Parts List D219368 2 fm Page 1 of 1 ...
Page 108: ......
Page 110: ......
Page 111: ......