The OEM TM-50 Controller
Chapter 2: Controller
19
To move the tape, press the arrow key on the
keypad pointing in the desired direction. The
tape will jog the selected distance each time
an arrow key is pressed. When the tape is
positioned correctly, press ESC to exit.
Mode
This screen (Figure 2.14) is used to set the
sealer type to be used and enable other sen-
sors and options.
Heat Seal
When heat seal is selected, the sealer dwell
time value is displayed on the Run Screen.
The heat seal switch on the sealer controls
panel must be turned ON in order for the heat
sealer to operate.
PSA Seal
If the system is switched to the PSA mode, the
heat seal switch should be turned OFF. The
dwell time value will be replaced by the letters
PSA on the Run Screen and the temperature
alarm is deactivated. Because no dwell time is
involved, the TM-50 has greater throughput
with a PSA sealer than with a heat sealer
since it does not need to pause every few
pockets for the sealer shoes to drop.
An asterisk will appear after HEAT SEAL or
PSA SEAL to indicate which is currently
enabled.
EPD
EPD is the empty pocket detection system. It
is self initializing if turned ON. It will not cause
a fault signal until after the first part is seen, or
300mm of carrier tape has passed under it.
Integration
Pressing 4>INTEGRATION on the MODE
screen will bring up the screen shown in Fig-
ure 2.27.
Vision
The Vision option is only active with the
Extended Software option.
Part Mark
The Part Mark option is only active with the
Extended Software option.
Auto Leader/Trailer
The Auto Leader screen will appear as shown
in Figure 2.16.
The automatic leader feature automatically
runs out tape for the leader of the next reel
once the current reel is completed. This is trig-
gered when the STOP COUNT is reached.
Using the auto leader feature both reduces
time spent between finishing a reel and begin-
ning a new and the waste of carrier tape that
usually results from manually running out the
tape and cutting off reels.
To enable the auto leader, determine the
length of leader desired (in millimeters) to fol-
low the last part placed and enter it on this
screen. The auto leader feature is disabled
when a value of zero (0) is entered.
1>HEAT SEAL*
2>PSA SEAL
3>EPD
4>INTEGRATION
Figure 2.14
1>VISION MODE OFF
2>PART MARK*
3>AUTO LdrTrlr*
-->
Figure 2.15
ENTER LEADER LENGTH
mm THEN PRESS ENT
0 and ENT = OFF
NOW 400
Figure 2.16
Summary of Contents for OEM TM-50 SMD
Page 2: ......
Page 4: ......
Page 10: ...Safety Warning Labels 61685113 fm vi ...
Page 28: ...16 OEM TM 50 User s Guide Machine Overview 61685225 fm ...
Page 43: ...6174007 fm Using the Vision Port Chapter 2 Controller 29 Vision Hookup Example Figure 2 33 ...
Page 74: ...60 OEM TM 50 User s Guide Electrical Connections 6174322 fm Figure 4 6 ...
Page 95: ...61004015 fm Appendix A Sensors A 1 Appendix A Sensors ...
Page 102: ...Service and Parts Contacts 61053915 fm Page 2 ...
Page 104: ......
Page 106: ...TM 50 OEM Sensors Spare Parts List D219368 2 fm Page 1 of 1 ...
Page 108: ......
Page 110: ......
Page 111: ......