6174007.fm
Using the Vision Port
Chapter 2: Controller
27
Vision Mode 2
DB9-1 is not used as a BUSY signal in this setup to allow Vision Systems without BUSY signals
to be integrated. In this instance, identical signals on both DB9-1 and DB9-3 are needed.
1. The OEM TM-50 will pull the TRIGGER signal (DB9-4) low for 10ms.
2. The OEM TM-50 will now start looking at the DB9-1 signal and the DB9-3 signal from the
vision system. The OEM TM-50 will search for 100ms time frame.
• For a PASS condition to occur, DB9-1 and DB9-3 must be pulled low for 100 ms. These
signals must begin within the OEM TM-50’s search time frame.
• If no signal is seen in that time period or if only one signal is seen, a part FAIL condition
will occur.
3. The OEM TM-50 will now look for the next TRIGGER signal.
Note
: A screen will appear if a failure is seen. Correct the problem and then press ENT to
retest the part, or press ESC to accept the part, count it, and move on.
The OEM TM-50 will not fail any parts until it has seen the first good part. This prevents fail-
ure notices before the first part reaches the camera.
Summary of Contents for OEM TM-50 SMD
Page 2: ......
Page 4: ......
Page 10: ...Safety Warning Labels 61685113 fm vi ...
Page 28: ...16 OEM TM 50 User s Guide Machine Overview 61685225 fm ...
Page 43: ...6174007 fm Using the Vision Port Chapter 2 Controller 29 Vision Hookup Example Figure 2 33 ...
Page 74: ...60 OEM TM 50 User s Guide Electrical Connections 6174322 fm Figure 4 6 ...
Page 95: ...61004015 fm Appendix A Sensors A 1 Appendix A Sensors ...
Page 102: ...Service and Parts Contacts 61053915 fm Page 2 ...
Page 104: ......
Page 106: ...TM 50 OEM Sensors Spare Parts List D219368 2 fm Page 1 of 1 ...
Page 108: ......
Page 110: ......
Page 111: ......