B- 2
TM-50 User’s Guide
Omron E5GC Temperature Controller
61574415.fm
Omron E5GC Temperature Controller
The Omron E5GC Temperature Controller is used to monitor and maintain a target temperature range for
the sealing shoes of the heat sealer. The heat sealer is equipped with two controllers, which control the
two sealer shoes (inside and outside) independently. The controllers are set by default to maintain a tem-
perature range equal to the set point +/-10 degrees for their respective sealer shoe. The controller does
this by comparing the present value (current temperature) to the set point (target temperature). It turns on
the heating element in the sealer shoe whenever the present value drops to 10 degrees below the set point
and allows them to cool when the present value rises to 10 degrees above the target temperature.
Adjusting the Set Points
To adjust the set point, simply press the increment or decrement keys (up and down arrows). The green
Set Point Display will show the changes and the controller will immediately begin adjusting the temperature
of the sealer shoes according to the new range that results. If a large adjustment is required, pressing and
holding the up or down arrow keys will increase or decrease the set point quickly.
Default Factory Settings
Refer to the Omron E5GC User’s Guide when necessary for more detailed technical information regarding
the operation of the termperature controllers. The directions below describe the factory settings set at the
time the controllers are installed at V-TEK, Inc.
Operation Level Settings (Figure 1.1)
1. Select the
Run-Stop
Settings
, displayed as
r-S
, by pressing the Mode Key. It
should be set to
rUn
.
2. Select the
Upper Limit Alarm
, displayed as
AL 1H
. It should be set to
10
.
3. Select the
Lower Limit Alarm
, displayed as
AL 1L
. It should be set to
10
.
Figure 1.1
Set Point (SP)
Display
Figure 2
Level Key
Temperature Unit
Mode Key
Down Arrow Key
Up Arrow Key
Present Value (PV) Display
Summary of Contents for OEM TM-50 SMD
Page 2: ......
Page 4: ......
Page 10: ...Safety Warning Labels 61685113 fm vi ...
Page 28: ...16 OEM TM 50 User s Guide Machine Overview 61685225 fm ...
Page 43: ...6174007 fm Using the Vision Port Chapter 2 Controller 29 Vision Hookup Example Figure 2 33 ...
Page 74: ...60 OEM TM 50 User s Guide Electrical Connections 6174322 fm Figure 4 6 ...
Page 95: ...61004015 fm Appendix A Sensors A 1 Appendix A Sensors ...
Page 102: ...Service and Parts Contacts 61053915 fm Page 2 ...
Page 104: ......
Page 106: ...TM 50 OEM Sensors Spare Parts List D219368 2 fm Page 1 of 1 ...
Page 108: ......
Page 110: ......
Page 111: ......