DE35-ST Operating Instructions
D292469I
93
5.
Adjust Closing Speed & Force
a.
The
Closing Speed
of the Gripper Finger is adjusted using the Needle
Valve located on top of the right Solenoid Valve.
b.
The
Closing Force
may be adjusted from zero up to about 20 grams using
the Front Panel Vacuum Regulator Control located to the right of the Die
Eject Speed Control. The closing speed is a function of the
Needle Valve
Setting
and the
Vacuum Force Control
.
6.
Adjust Vacuum.
a.
Rotate the Regulator Control Knob on Front Panel clockwise to increase
the vacuum, thus increasing gripper pressure.
Replace Gripper Fingers
The Gripper Fingers are locked in the Gripper Arms by #2-56 set screws pushing on a
1/16-diameter ball bearing at the tip. The ball minimizes the tendency of the needle
moving when the setscrew is tightened.
The Gripper Finger is the same diameter as a Die Ejector Needle, so a discarded Die Eject
Needle may be used if the Gripper Finger needs to be replaced. While not essential, a
soft vinyl sleeve pushed over the Gripper Finger makes a very soft die contact surface.
Summary of Contents for Royce DE35-ST
Page 2: ...2 D292469I BLANK PAGE...
Page 26: ...DE35 ST Operating Instructions D292469I 25 BLANK PAGE...
Page 45: ...44 D292469I BLANK PAGE...
Page 57: ...56 D292469I BLANK PAGE...
Page 83: ...82 D292469I NOTE The Die Ejector is automatically switched off after about 1 minute...
Page 95: ...94 D292469I Blank Page...
Page 107: ...106 D292469I Blank Page...
Page 130: ...DE35 ST Operating Instructions D292469I 129 Blank Page...
Page 132: ...DE35 ST Operating Instructions D292469I 131 Blank Page...
Page 134: ...DE35 ST Operating Instructions D292469I 133 Blank Page...