D292105.9b.fm
System Alarm Messages
Chapter 7: Troubleshooting
7-21
Error Message Table
Error Condition
Solution
“The system was unable to suc-
cessfully pick from the current
location.”
Nozzle is not picking parts from the
Bowl Feeder
. Check
the following:
- Feeder is empty.
- Linear Track is jammed.
- Pick height is too high.
“The heat seal temperature is
not within range.”
The
Heat Sealer
on the
Taper
has not reached the cor-
rect temperature. Wait until sealer has had enough time
to reach the correct temperature.
“The heat sealer was disabled
due to inactivity.”
The
Heat Sealer
on the
Taper
was automatically dis-
abled after being inactive for more than 40 minutes. Wait
until sealer has had enough time to reach the correct
temperature, then proceed.
“The tape jam sensor has been
activated.”
Check carrier tape prior to
Sealer
to ensure part is not
sticking out of pocket. Remove any obstructions, then
resume operation.
“The cover tape is running low.”
Refill cover tape.
“A part has failed visual inspec-
tion in the carrier tape.”
Check the following:
- Part is incorrectly oriented.
- Part mark is missing or obscured.
- Part is missing.
“The inspection system has
timed out.”
Check the following:
- Vision system is not connected to power
- Vision System is setup incorrectly.
“The last part picked was lost
between the pick and place
point.”
Check the following:
-
Vacuum Sensor
is set correctly.
- The correct
Nozzle Tip
is installed.
-
Pick Position
is centered correctly.
“There’s not a part available to
place.”
Pick a part and proceed.
“The job has been completed.
Reset the job to continue pro-
cessing.”
Reset the job.
“The system has already placed
more parts than the entered
quantity.”
The job quantity was changed after parts have been run.