SMC ZSE30 Vacuum Sensor
D291842.11.fm
A-5
Appendix A: Sensors
one is present, set the threshold closer to the pressure reading when no part is on the
nozzle. In this way, the optimum setting for each specific part can be reached.
Initial Factory Settings
If for some reason the sensor needs to be re-initialized to the default factory settings, follow the
steps below:
1.
Press and hold the
Set
button for at least two seconds. The sensor will enter initialization
mode. The first setting to appear will be the
Indication Unit
setting. This should be set to
PA
. Use the
Up Arrows
and
Down Arrows
to adjust this, if necessary.
2.
Press the
Set
button to advance to the
Display Color
setting. This should be set to
Sor
(Red/ON).
3.
The next setting is the
Operation
mode setting. This should be set to
HyS
(hysteresis).
4.
The next setting is the
Output
mode setting. This should be set to
nC
(normally closed). If
this setting is incorrect, the sensor will function backwards, such that the machine will not
detect a part when is on the nozzle and detect a part when no part is present.
5.
The next setting is the
Response Time
setting. This should be set to
2.5.
6.
The final setting is the
Auto Preset
setting. This should be set to
mAn
(manual).
7.
Press the
Set
button to return to
Normal Operation
mode.