3-20
TM-403 User’s Guide
Taper Tab
D292105.6a.fm
4.
Pressing the right
Arrow
button in the third
Taper Setup
screens opens the final
Taper
Setup
screen. The fourth
Taper Setup
screen focuses on
Leader
and
Sensor
settings.
A.
The
Tape Jam Sensor
Enabled/Disabled
button turns the
Tape Jam Sensor
on
and off. The
Tape Jam Sensor
registers a tape jam whenever something pro-
trudes above the top of the carrier tape pocket. This might be caused by a mis-
placed part, a pocket that has been loaded with two parts or by a buckle in the
tape.
When the
Tape Jam Sensor
is activated, the job that is being run is paused and
an error message appears on the HMI screen. The recommended setting for the
Tape Jam Sensor
is
Enabled
.
The
Low Cover Sensor
Enabled/
Disabled
button turns the
Low Cover Tape Sen-
sor
on and off. The
Low Cover Tape Sensor
detects when the cover tape reel is
running low. When the
Low Cover Tape Sensor
is activated, an error message
appears on the HMI screen. The recommended setting for the
Low Cover Tape
Sensor
is
Enabled
.
Note:
The
Low Cover
error message is only displayed once during a job.
B.
When Leader State is enabled, the TM-402 will create a leader of the specified
length at the end of the job.
The
Leader Length
field is only active when
Leader State
is enabled. Enter the
desired leader length in millimeters in the field.
Note:
The TM-402 will use these settings for the current job. To save
Taper Settings
for
future jobs, go to the
Job Tab,
select a job name and
Save
. If settings are not saved, all
data is lost when the TM-402 is powered off.
Taper Screen 4
A
B