5
If any par
t o
f the applian
ce becom
es damag
ed or fr
actured, it must be replaced by a V-TÜF engineer.
Opera
�
ng Inst
ruc�ons
All V-TUF
P
r
o
ducts
shou
ld arrive
to
the c
o
nsumer as ready t
o
use immediately. Simply, plug in
to
the mains
outlet,
then start the machin
e by mo
ving th
e o
n/
off sw
itch
to
the
‘on’
p
os
i
�on.
Motor Prot
ec
�on
Filter & Exhaust Filter
The
moto
r pr
otec�o
n
fi
lter (21) is
on
ly accessible by rem
ov
ing the vacuum head. Li
�
the
mo
t
or
pr
otec�o
n
fi
lter up by the bracket. When replacing the
moto
r pr
otec�on
fi
lter make sure that it is pressed in
posi�on
�ghtly
. The
motor prot
e
c�o
n
fi
lter will pr
o
tect t
he mo
t
or
s when vacuuming wet & dry material.
If the
moto
r p
rotec�o
n
fi
lter
(fi
g 21) is used
for
wet suc
�on.
It must be
sto
red
o
utside the vacuum
to
dry
before
being used again. If this is pr
o
blem
order
a spare
fi
lter (21. Dust screen) and alternate the use. This
fi
l
ter should
be cleaned when it is dirty.
Motor Prot
ec
�on
fi
lters:
VTVS8021 (FIG.21) Dust Screen VTVS7020L WET
on
ly
filt
er
For WET
ONLY use the Machine is suppled with the
Change the exhaust
fi
lter at the same
�
me as the
moto
r p
rotec�on
fi
lter.
To
do
this, carefully rem
ov
e the
fi
lter
retaining rings and put them
to
the side. Next pull the
enfo
rcement strips
of
the exhaust
fi
lter
out
o
f the
ho
using sl
ot
and rem
ov
e the
exhaust fi
lter f
ro
m the
ho
using.
When reassembling, please ensure the exhaust
fi
lter is
fi�ed
corr
ectly in the
ho
using sl
ots
and the
fi
lter
retaining rings are installed c
or
rectly.
Only
use genuine V-TÜF
repl
acements on the a
pplian
ce. V-TUF wi
ll
not
accep
t
re
s
p
onsi
bility
for
damage to
the machine o
r to
the use
r
due to insu
ffi
cient
le
v
els of
fil
t
r
a
�on
f
or
the a
pplica�
on.
Acc
essories