background image

Installation instructions

Built-in variants of gas hob
Dials

1014402-R05

14/08/2019

1014402-R05

8

Flush mounted

Surface mounted

A

Place the appliance tray in the kitchen cabinet and up
and over the threaded rods.

A

Lift the base plate back onto the base.

B

First tighten the two knurled nuts in the corners.

B

Screw in the screws along the circumference of the ap-
pliance.

C

Screw the rest of the nuts on the threaded rods along
the circumference of the appliance.

C

Place the appliance in the worktop cut-out again and
centre, then fit any adjusting braces again.

Replace the drawers or cabinet front.

Mount the burner plates and tighten with screws.

Put control knobs back on.

Put back the burners and pan supports.

Reconnect the appliance to the electricity and gas mains.

After the nozzles have been changed, leak testing must be carried out and then the flame pattern checked in the
min./max. position for each burner.

Nozzle table

Change injector nozzles using a 7-inch socket wrench or corresponding wrench.

Key

Designation

A

Injector, ø in hundredths of a mm

B

Bypass, ø in hundredths of a mm / letter code

For the appliances, the following gas types are available:

Gas type

Test

gas

Connection

pressure

Injector nozzles (ø in hundredths of a mm)

Wok burner

Economy burner Standard burner Rapid burner

A inside B outside A inside B outside

A

B

A

B

A

B

Natural gas 
AU/NZ

G20

1.0 kPa

80

2 × 161

50

98

92

57

116

60

155

77

Universal 
liquid gas 
butane/propane

G31

2.75 kPa

46

2 × 80

26

54

50

30

66

31

85

41

Affixing the gas sticker

After conversion to another gas type, the sticker supplied with the nozzle set must be affixed in the appropriate place on the identifica-
tion plate.

The appliance must be tested for leak tightness before using for the first time.

Summary of Contents for 31075 Series

Page 1: ...r low voltage installations and fire protection must be strictly observed All leak tests should be done with a soapy water solution Never use an open flame to check for leaks All leak tests should be...

Page 2: ...surface mounted combination of several hobs 1019199 Flush installation Designation Article no Steel angle set hob size 60 H63772 Designation Art no Instant adhesive for installation of the steel angle...

Page 3: ...face to the underside of the gas connection Ri Corner radii of appliance for base plate Ra Outer corner radii of cut out S Minimum distance between the top of the work surfaces and any drawer T Minimu...

Page 4: ...iance for base plate Ra Outer corner radii of cut out S Minimum distance between the top of the work surfaces and any drawer T Minimum distance between the cut out in the back and any drawer Installat...

Page 5: ...es with basic insulation must not be accessible Check old installa tions Refer to the identification plate for information on the required mains voltage current type and fuse protection The connection...

Page 6: ...meters above sea level a re duced performance must be expected Gas connection The gas connection and the conversion to another gas type must be carried out by an authorized installer 51 46 GAS641 51...

Page 7: ...ll the nozzles are numbered to avoid any mix up Always disconnect the appliance from the electricity and gas mains before changing the nozzles Changing the injector nozzles Remove the pan supports and...

Page 8: ...After the nozzles have been changed leak testing must be carried out and then the flame pattern checked in the min max position for each burner Nozzle table Change injector nozzles using a 7 inch sock...

Reviews: