Installation instructions
Built-in variants of gas hob
Dials
1014402-R05
14/08/2019
1014402-R05
1
The appliance must be installed by qualified personnel only. Each step must be carried out and checked in full in the
order specified.
Check that the local connection conditions (gas type and gas pressure) and the appliance setting match before con-
necting the appliance.
The default values for this appliance are provided on the information plate (or on the identification plate).
This appliance is not connected to a combustion by-product outlet. It must be set up and connected according to the
applicable installation conditions. Particular attention must be paid to the relevant ventilation requirements.
If installing into a combustible material, the guidelines and standards for low-voltage installations and fire protection
must be strictly observed.
All leak tests should be done with a soapy water solution. Never use an open flame to check for leaks!
All leak tests should be done with a soapy water solution. Never use an open flame to check for leaks!
Validity
These installation instructions apply to the following models:
Model number
Type
Appliance class
31089
GAS641GKAZ
Class 3
DIN EN 30-1-1
31075
GAS731GKBZ
General notes
Identification plate
The identification plate and stickers with the permissible
gas types and safety precautions are located on the under-
side of the hob.
Identification plate
Depending on
appliance, plate
with additional
information
▸
Affix the second identification plate (supplied) in an accessible position behind the front of the fitted cabinet beneath the appliance.
Care and maintenance
▸
Follow the care and cleaning advice in the operating instructions.
▸
Follow the basic maintenance advice in the operating instructions.