Installation instructions
Built-in variants of gas hob
Dials
1014402-R05
14/08/2019
1014402-R05
4
Flush installation
The layout of the hob to be fitted may differ from the hob illustrated!
H
Y – Y
B
A
S*
≥85
T
≥90
Drawer/
cabinet
Side panel
Ra
8.5
0
-1
8.5
0
-0.5
Steel angle bonded
or screw mounted
Detail Z
R0–5
8.5
+1
0
8.5
+1
0
C
Y
Y
GAS731GKBZ (31075)
691
Ri
50
1
H
A
50
7±1
≥41
.5
≥
41.5
600
Z
697±1
D
60
0
Z
600
577±1
507±1
≥41.5
≥41.5
A
600
Ri
H
50
1
Y
Y
571
GAS641GSAZ (31089)
* The required clearance must be observed!
Type
A Depends on producer
B
H
Corner radius Ra/Ri
C/D
GAS641GKAZ
≥30 mm
≥175 mm
88 mm
5/1.5 mm
560/490 mm
GAS731GKBZ
680/490 mm
A
Worktop depth
B
Required clearance for service replacement
H
Dimension from the top of the work surface to the underside of the gas connection
Ri
Corner radii of appliance for base plate
Ra
Outer corner radii of cut-out
S
Minimum distance between the top of the work surfaces and any drawer
T
Minimum distance between the cut-out in the back and any drawer
Installation
▸
Create an accurate installation cut-out.
–
The mounting surface can be reamed out or created by installing wood/stone supports or using the steel angle set (see Ac-
cessories).
Access to the appliance from below via the entire cut-out area must be guaranteed. For servicing purposes, the appliance
base can be removed from below.
▸
Prepare the cut-out and appliance according to the specifications in the enclosed cementing-in instructions and align the appliance
in the cut-out.
▸
Fit the four adjusting braces along the circumference of the appliance to the bore holes provided and tension the appliance against
the worktop.
▸
Carefully cement the appliance in and leave the silicone sealant to dry for at least 24 hours.
▸
Connect to the electrical mains connection before inserting the appliance, if necessary.