3 Operating the appliance
3
Operating the appliance
3.1
Using for the first time
Appliance configuration
The appliance is for use in the extraction mode. The appliance is set up by default for
use in the
extraction mode
. The cleaning interval for the metal grease filters is 20 operat-
ing hours.
Setting up the appliance for use in the extraction mode
▸ Switch the appliance and the illumination off.
▸ Hold the
button depressed for 3 seconds.
–
The
display symbol and, depending on the cleaning interval setting set,
,
or flash.
▸
While they are flashing:
Hold the
button depressed again for 3 seconds.
–
The
display symbol and, depending on the cleaning interval setting set,
,
or are no longer displayed.
–
The appliance is now configured for the extraction mode and the saturation indic-
ator for the activated charcoal filter is
deactivated
.
Setting up the appliance for use in the recirculation mode
▸ Switch the appliance and the illumination off.
▸ Hold the
button depressed for 3 seconds.
–
The
display symbol and, depending on the cleaning interval setting set,
,
or flash.
▸ To change the cleaning interval for the activated charcoal filter: Touch the
button
repeatedly until the corresponding display symbol
+
, or flashes (see table).
–
The setting selected will be activated after 5 seconds.
–
The
display symbol and, depending on the cleaning interval setting set,
,
or are no longer displayed.
–
The appliance is now configured for the recirculation mode and the saturation indic-
ator for the activated charcoal filter is
activated
.
Cleaning interval for activated charcoal filter
Cooking intensity
Saturation indicator after
Flashing display symbol
Less frequent and/or light cook-
ing aromas
240 hours
+
Standard (factory default setting)
180 hours
+
Frequent and/or strong cooking
aromas
120 hours
+