background image

5 Trouble-shooting

Trouble-shooting

This section lists faults that can be solved simply by following the instructions given. If
the fault cannot be remedied, please call Customer Services.
Before calling Customer Services: Please note down the serial number (for SN, see iden-
tification plate under «Technical data») and what led to the fault.

Malfunction

Possible cause

Solution

Appliance is not
working.

Interruption in the power
supply.

▸ Check the power supply.
▸ Change the fuse.
▸ Reset the automatic circuit

breaker.

Illumination is not
working.

LED light bulb is defective. ▸ Contact Customer Services.

Malfunction

Possible cause

Solution

Appliance is not ex-
tracting enough air.

Metal grease filters are
dirty.

▸ Clean metal grease filters.

Recirculation mode only:
Activated charcoal filters
are saturated.

▸ Clean and reactivate or replace

activated charcoal filters.

Extraction mode only: In-
sufficient fresh air intake.

▸ Ensure fresh air intake is suffi-

cient.

Accessories and spare parts

Please give product family of the appliance and exact designation of the accessory or
spare part when ordering parts. 

Metal grease filter (example is shown;
actual filter depends on model)

Remote control

15

Summary of Contents for AiroClearWall V4000

Page 1: ...Operating instructions AiroClearWall V4000 Range hood ...

Page 2: ...ns Modifications Text diagrams and data correspond to the technical standard of the appliance at the time these operating instructions went to press The right to make technical modifications for the purpose of the further development of the appliances is reserved Validity These operating instructions apply to Model designation Type Size system AiroClearWall V4000 AW4T 62026 90 AiroClearWall V4000 ...

Page 3: ...Using for the first time 10 3 2 Switching the appliance on off 11 3 3 Selecting power level 11 3 4 Illumination 11 3 5 After running time 12 3 6 Wipe protection 12 3 7 Saturation indicators 12 3 8 Remote control accessories 13 4 Care and maintenance 13 4 1 Cleaning the housing 13 4 2 Metal grease filters 14 4 3 Reset saturation indicator alarm 14 4 4 Replacing the LED light bulbs 14 5 Trouble shoo...

Page 4: ...me This appliance can be used by children aged 8 and above and by persons with reduced physical sensory or mental capabilities or lack of experi ence and or knowledge provided they are supervised or have been instructed on the safe use of the appliance and have understood the haz ards involved Children shall not play with the appliance Cleaning and user mainten ance shall not be undertaken by chil...

Page 5: ...must be observed See the in stallation instructions for this WARNING Before replacing the light bulb ensure the ap pliance is switched off and disconnected from the mains power supply to avoid pos sible electric shock When replacing a light bulb the maximum wattage rating of replaceable light bulbs must be visible This appliance is intended for use in the home and similar settings such as in staff...

Page 6: ...he complete appliance at any time without causing any damage 1 5 Instructions for use Before using for the first time The appliance must be installed and connected to the electricity supply in accordance with the separate installa tion instructions Have a qualified fitter electrician carry out the necessary work Observe the official regulations for the exhaust air layout Dispose of the packaging m...

Page 7: ...se a steam cleaner If water gets inside the appliance it can cause damage Accessible parts may become hot when used with cooking appliances Caution Burns hazard Do not leave the appliance unattended when deep frying on the cooking sur face The cooking oil in the deep frying appliance could overheat and catch fire Constantly monitor the temperature of the cooking oil keeping it below the temperatur...

Page 8: ...e cooking surface The metal grease filters clean the extracted air which is then passed through a connecting pipe fit ted with an integrated non return valve and through the air duct to the outside When in use ensure there is a sufficient supply of fresh air to replace the air that is being extracted 2 3 Features 1 hood body is equipped with extractor fan LED lighting operating and display ele men...

Page 9: ...Display symbols Wipe protection After running time Power level 1 Power level 2 Power level 3 Intensive level flashing Saturation indicator for grease filter Saturation indicator for activated charcoal filter recirculation air only not active with this particular model Depending on the model and features the specification of your appliance may dif fer in individual details from the standard specifi...

Page 10: ...he activated charcoal filter is deactivated Setting up the appliance for use in the recirculation mode Switch the appliance and the illumination off Hold the button depressed for 3 seconds The display symbol and depending on the cleaning interval setting set or flash To change the cleaning interval for the activated charcoal filter Touch the button repeatedly until the corresponding display symbol...

Page 11: ...evel and the corresponding symbol or illuminates in the display Intensive level The intensive power level runs for 5 minutes It is used for short bursts of intensive ex traction of cooking fumes and smells e g when searing meat The intensive power level then switches back to the previously selected power level or switches the appliance off Hold the button depressed while the fan is running The app...

Page 12: ...fore start ing to cook Leave the appliance running for a few minutes after cooking so as to extract all the cooking smells 3 6 Wipe protection The wipe protection function temporarily deactivates the keypad control panel and is useful for quickly cleaning the operating elements Switch the appliance and the illumination off Hold the button depressed for 5 seconds The wipe protection function is act...

Page 13: ...evel Activate after running time Switch the illumination on off Do not place the remote control near any heat sources Dispose of the batteries at a suitable recycling point in accordance with national regulations 4 Care and maintenance 4 1 Cleaning the housing Make sure no water gets inside the appliance If water gets into the appliance it can cause damage Do not use abrasive cleaners scouring pad...

Page 14: ...ater and mild detergent Clean rinse well with clean cold water and then wipe dry Grease filters can be used again after being cleaned Put the metal grease filters back Reset saturation indicator alarm see page 14 Cleaning may cause the metal grease filters to become slightly discoloured How ever this will not affect the functioning of the filters in any way 4 3 Reset saturation indicator alarm Res...

Page 15: ...matic circuit breaker Illumination is not working LED light bulb is defective Contact Customer Services Malfunction Possible cause Solution Appliance is not ex tracting enough air Metal grease filters are dirty Clean metal grease filters Recirculation mode only Activated charcoal filters are saturated Clean and reactivate or replace activated charcoal filters Extraction mode only In sufficient fre...

Page 16: ...e scope of delivery and should be retained for the purpose of appliance identification 7 1 Fan power Extraction capacity according to EN 61591 Exhaust air output with ø200 mm ø150 mm Power level 1 640 m3 h 620 m3 h Power level 2 961 m3 h 846 m3 h Power level 3 1165 m3 h 957 m3 h Intensive level 1262 m3 h 995 m3 h 7 2 Light bulbs LED Type Rated output Rated voltage AW4T 62026 2 2 W 12VDC AW4T 62031...

Page 17: ...e carried out by a qualified electrician Then cut the mains cable off flush with the appliance 8 3 Disposal The crossed out wheeled bin symbol requires the separate collection of waste electrical and electronic equipment WEEE Such equipment can contain hazardous environmentally harmful materials These appliances are to be handed over to a designated collection point for the recyc ling of electrica...

Page 18: ...s Road Scotts Square 03 11 12 13 228209 Singapore SINGAPORE GB IE V ZUG UK Ltd 27 Wigmore Street London W1U 1PN GREAT BRITAIN TH V ZUG Thailand Ltd 140 36 17th Floor ITF Tower Silom Road Suriyawong Sub district Bangrak District Bangkok 10500 THAILAND HK MO V ZUG Hong Kong Co Ltd 12 F 8 Russell Street Causeway Bay HONG KONG TR GÜRELLER Anchor Sit 3A 1 2 Çayyolu 06690 ÇANKAYA ANKARA TURKEY IT Frigo ...

Page 19: ... I Identification plate 16 Illumination 11 Initial set up 6 M Model designation 2 N Notes 20 O Operating and display elements 9 Operating the appliance 10 R Remote control 13 S Safety precautions Before using for the first time 6 Correct use 6 Instructions for use 6 Note on use 6 Safety warnings Appliance installation 6 Appliance specific 5 General 4 Saturation indicator 12 Selecting power level 1...

Page 20: ...20 10 Notes ...

Page 21: ...21 ...

Page 22: ...22 ...

Page 23: ... your appliance You will find them on the identification plate of your appliance My appliance information SN __________________________ Appliance ________________________________ Please have this appliance information to hand when contacting V ZUG Thank you Remove the metal grease filters The identification plate is located on the inside of the appliance A second identification plate is included i...

Page 24: ...r running time Display symbols Wipe protection After running time Power level 1 Power level 2 Power level 3 Intensive level flashing Saturation indicator for grease filter Saturation indicator for activated charcoal filter recirculation air only not active with this particular model V ZUG Ltd Industriestrasse 66 CH 6302 Zug info vzug com www vzug com 1085150 04 ...

Reviews: