4 Operation
4
Operation
4.1
Switching the appliance on
▸ Plug in the appliance at the mains socket.
–
«OF» appears on the left- and right-hand side of the display for 30 seconds.
▸ Hold the
button depressed for 3 seconds.
–
The appliance is switched on.
A newly installed appliance takes around 13 hours (empty state / without any food
inside) to reach normal operating temperatures. The corresponding zones
con-
tinue to flash in the display until the temperatures are reached.
4.2
Setting the temperature
Setting range
The required temperature for each zone is entered one after the other.
Temperature zone
Degrees Celsius [°C] Fahrenheit [°F]
Unfrozen compartment
Setting range
3 to 8
38 to 46
Recommended setting 5
41
ColdFresh
Setting range
0 to 3
32 to 37
Recommended setting 1
34
Freezer compartment
Setting range
-24 to -14
-11 to 6
Recommended setting -18
0
Second refrigerator com-
partment
(MonoFridge
is activated)
Setting range
2 to 14
36 to 57
If the freezer compartment is used as a second refrigerator compartment (MonoFridge
is activated), the temperature in the unfrozen compartment and in the ColdFresh temper-
ature zone is set at 5 °C (41 °F) and 1 °C (34 °F) respectively.
If the temperature in the ColdFresh temperature zone is set at 0 °C (32 °F), de-
pending on what is being stored, cold damage can occur.
Procedure
▸ Open the refrigerator compartment door.
–
The selected set temperature values are displayed for 5 seconds: the temperature
of the unfrozen compartment alternates with that of the ColdFresh temperature
zone on the left-hand side of the display
–
and then the actual temperature values are displayed.
▸ Touch the
,
or
button.
–
The temperature display for the unfrozen compartment flashes on the left-hand side
of the display.
▸ Touch the
or
button and select the desired temperature for the
unfrozen com-
partment
.
10
Summary of Contents for CombiCooler V4000 178KNI
Page 38: ...38 16 Notes ...