Service manual Platform 2014-2016, V-ZUG KT 
 
 

 

 

 
1036497-00_ae   gedruckt 

 

INSTALLATION 

2.1 

Installation data 

 

 

Allow the appliance to stand for one hour before putting it into 
operation so that the oil can flow back into the compressor. 

 

Niche width 

Interior       550 mm CH version  

Exterior     600 mm EU version (interior 560 – 568; use side adapter profile) 

 

Temperature range 

Cooling compartment (CC) 
+2 to +9°C   Recommended setting: +5°C 

+3 to +9°C   Recommended setting: +5°C  for Cooltronic/eco 

Freezer compartment (FC) 
-14 to -24°C    Recommended setting: -18°C (not possible with all models) 

 

Electrical connection 

220 - 240V / 50Hz  Alternating current (AC) 

 

 

 

Summary of Contents for Cooltronic

Page 1: ...KT 1036497 00_ae gedruckt Service instructions for product line 2014 15 16 Cooltronic Cooltronic eco 51047 51069 EK1423 EA EK1423 EE Noblesse Noblesse eco 51046 51068 EK1422TF EA EK1422TF EE Prestige...

Page 2: ...www vzug com Service manual 1036497 00 AE 1 Serial production created 27 09 2017 waa modified 28 09 2017 User Agent checked 28 09 2017 asan 2 61 Service manual Platform 2014 2016 V ZUG KT 1036497 00_...

Page 3: ...67 info vzug com www vzug com Service manual 1036497 00 AE 1 Serial production created 27 09 2017 waa modified 28 09 2017 User Agent checked 28 09 2017 asan 3 61 Service manual Platform 2014 2016 V ZU...

Page 4: ...ss shelves 18 4 OPERATION 19 4 1 Operating and display elements 19 4 2 Main ON OFF button 20 4 3 Setting the temperature 20 4 4 Alarm functions 21 4 5 Special functions 21 4 6 Switching special operat...

Page 5: ...cidental contact must be ensured through the installation of the appliance The appliance must be installed and connected to the electricity supply in accordance with the separate installation instruct...

Page 6: ...ON 2 1 Installation data Allow the appliance to stand for one hour before putting it into operation so that the oil can flow back into the compressor Niche width Interior 550 mm CH version Exterior 60...

Page 7: ...com www vzug com Service manual 1036497 00 AE 1 Serial production created 27 09 2017 waa modified 28 09 2017 User Agent checked 28 09 2017 asan 7 61 Service manual Platform 2014 2016 V ZUG KT 1036497...

Page 8: ...g com Service manual 1036497 00 AE 1 Serial production created 27 09 2017 waa modified 28 09 2017 User Agent checked 28 09 2017 asan 8 61 Service manual Platform 2014 2016 V ZUG KT 1036497 00_ae gedru...

Page 9: ...1 58 767 67 67 Fax 41 58 767 67 67 info vzug com www vzug com Service manual 1036497 00 AE 1 Serial production created 27 09 2017 waa modified 28 09 2017 User Agent checked 28 09 2017 asan 9 61 Servic...

Page 10: ...ual Platform 2014 2016 V ZUG KT 1036497 00_ae gedruckt 2 door version that can be fitted with door panel 2 3 Replacing or converting integrable door The cover is asymmetrical For appliance door conver...

Page 11: ...ial production created 27 09 2017 waa modified 28 09 2017 User Agent checked 28 09 2017 asan 11 61 Service manual Platform 2014 2016 V ZUG KT 1036497 00_ae gedruckt 2 Remove hinge cover from hinge at...

Page 12: ...2017 waa modified 28 09 2017 User Agent checked 28 09 2017 asan 12 61 Service manual Platform 2014 2016 V ZUG KT 1036497 00_ae gedruckt 4 Remove wooden door panel if any a Remove white plugs b Remove...

Page 13: ...ated 27 09 2017 waa modified 28 09 2017 User Agent checked 28 09 2017 asan 13 61 Service manual Platform 2014 2016 V ZUG KT 1036497 00_ae gedruckt e f 5 Unscrew appliance door from hinge 6 Unscrew hin...

Page 14: ...nel Mount panel and slide from left to right 10 To put back wooden door panel if any reverse steps in point 4 2 4 Adjusting integrable door Cannot be adjusted using hinges Adjust using wooden door pan...

Page 15: ...T 1036497 00_ae gedruckt 1 Remove hinge covers 2 Unscrew handle 3 Unscrew hinge 4 Push hinge bolts in at top and bottom so as to be able to remove hinge lever 5 Put bearing bushing on other side of hi...

Page 16: ...7 Fax 41 58 767 67 67 info vzug com www vzug com Service manual 1036497 00 AE 1 Serial production created 27 09 2017 waa modified 28 09 2017 User Agent checked 28 09 2017 asan 16 61 Service manual Pla...

Page 17: ...7 67 67 Fax 41 58 767 67 67 info vzug com www vzug com Service manual 1036497 00 AE 1 Serial production created 27 09 2017 waa modified 28 09 2017 User Agent checked 28 09 2017 asan 17 61 Service manu...

Page 18: ...cold storage compartment evaporator only applies to Cooltronic eco 5 Sensor for freezer compartment only applies to Cooltronic eco Noblesse Prestige T eco P eco 6 Defrosting element with height speci...

Page 19: ...ts Cooltronic Cooltronic eco Prestige Prestige T Prestige eco Prestige P eco Noblesse Noblesse eco Classic eco Futura eco De Luxe De Luxe eco Perfect Perfect eco Buttons 1 Main ON OFF button 2 Tempera...

Page 20: ...ss the preselection button until the corresponding temperature symbol flashes 2 Touch temperature setting button once or more Each time sensor is touched cooling or freezing compartment temperature ri...

Page 21: ...tic signal is emitted For appliances with an actual temperature display the temperature display also flashes If the temperature in the cold storage compartment rises above 10 C or falls below 3 5 C th...

Page 22: ...vated and the refrigerator section will be cooled down again The actual temperature appears in the temperature display for the cooling compartment Sabbath Same as with holiday mode except press specia...

Page 23: ...on model 2 0 is displayed Test all buttons including door switch Whenever a button is pressed an acoustic door alarm is emitted and the counter on the display is increased If no button is pressed with...

Page 24: ...of the cold storage compartment is too warm Cooltronic Er 3 The temperature of the evaporator sensor in the cold storage compartment is too warm Cooltronic Er 4 The temperature difference reached in t...

Page 25: ...gedruckt F1 Air sensor for cooling compartment missing or defective All F2 Air sensor for freezer compartment missing or defective Prestige Noblesse F2 Air sensor for cold storage compartment missing...

Page 26: ...nt on Fast cooling symbol 4 Use the main ON OFF button to retrieve the following information t0 Temperature of the onboard control sensor t1 Temperature of the air sensor in the cooling compartment t2...

Page 27: ...reezer compartment Cooltronic eco Noblesse eco Prestige T eco P eco Classic eco Futura eco Nc 01 Cold storage compartment factory default setting temperature level 01 Cooltronic eco Nc 02 Cold storage...

Page 28: ...atform 2014 2016 V ZUG KT 1036497 00_ae gedruckt ED 00 software version number is displayed P0 01 parameter set number is displayed ID 01 ID number is displayed If no button is pressed within 20 minut...

Page 29: ...zug com www vzug com Service manual 1036497 00 AE 1 Serial production created 27 09 2017 waa modified 28 09 2017 User Agent checked 28 09 2017 asan 29 61 Service manual Platform 2014 2016 V ZUG KT 103...

Page 30: ...vice manual Platform 2014 2016 V ZUG KT 1036497 00_ae gedruckt Schematic diagram of cold circuit for Cooltronic eco Image Schematic diagram of cold circuit for Noblesse eco The wire tube evaporator of...

Page 31: ...ed 27 09 2017 waa modified 28 09 2017 User Agent checked 28 09 2017 asan 31 61 Service manual Platform 2014 2016 V ZUG KT 1036497 00_ae gedruckt Schematic diagram of cold circuit for Noblesse Prestige...

Page 32: ...28 09 2017 User Agent checked 28 09 2017 asan 32 61 Service manual Platform 2014 2016 V ZUG KT 1036497 00_ae gedruckt Schematic diagram of cold circuit for Classic eco and Futura eco The wire tube eva...

Page 33: ...2017 User Agent checked 28 09 2017 asan 33 61 Service manual Platform 2014 2016 V ZUG KT 1036497 00_ae gedruckt Schematic diagram of cold circuit for Perfect Perfect eco and De Luxe De Luxe eco The t...

Page 34: ...ic control unit contact assignment Cooltronic eco Phase L brown Neutral conductor N blue Valve L brown Valve N blue Sensor for evaporator CSC Sensor for air temp CSC brown Sensor for cooling compartme...

Page 35: ...Noblesse Noblesse eco Prestige Prestige T Prestige eco Prestige P eco Phase L brown Neutral conductor N blue Valve L brown Valve N blue Sensor for freezer compartment brown Sensor for cooling compart...

Page 36: ...2017 asan 36 61 Service manual Platform 2014 2016 V ZUG KT 1036497 00_ae gedruckt Classic eco Futura eco Phase L brown Neutral conductor N blue Sensor for evaporator brown Sensor for cooling compartm...

Page 37: ...G KT 1036497 00_ae gedruckt De Luxe De Luxe eco Perfect Perfect eco Compressor black A Phase L brown Neutral conductor N blue Sensor for evaporator brown Sensor for cooling compartment brown Sensor fo...

Page 38: ...vzug com Service manual 1036497 00 AE 1 Serial production created 27 09 2017 waa modified 28 09 2017 User Agent checked 28 09 2017 asan 38 61 Service manual Platform 2014 2016 V ZUG KT 1036497 00_ae g...

Page 39: ...767 67 67 info vzug com www vzug com Service manual 1036497 00 AE 1 Serial production created 27 09 2017 waa modified 28 09 2017 User Agent checked 28 09 2017 asan 39 61 Service manual Platform 2014...

Page 40: ...Fax 41 58 767 67 67 info vzug com www vzug com Service manual 1036497 00 AE 1 Serial production created 27 09 2017 waa modified 28 09 2017 User Agent checked 28 09 2017 asan 40 61 Service manual Platf...

Page 41: ...Phase 1 Phase 2a Phase 2b Phase 3 Phase 1 Appliance is pre cooled for no longer than 30 mins Phase 2a The compressor is switched off until the temperature sensor for the evaporator has reached 5 5 C D...

Page 42: ...ct PCB defective F3 Evaporator temperature of cold storage compartment Cooltronic eco Temperature sensor of freezing compartment defective connector contact PCB defective F4 Air temperature of freezer...

Page 43: ...be stopped by briefly pressing any button 3 Check door seal Replace door seal see section 7 5 4 Appliance standing next to heat source 5 Door is not hanging straight Set the door see section Fehler V...

Page 44: ...ise 1 Vibration above niche Check installation Does appliance stand straight in niche 2 Compressor defective Replace compressor see section 7 13 3 Air in circuit Evacuate refrigerant cooling circuit a...

Page 45: ...tform 2014 2016 V ZUG KT 1036497 00_ae gedruckt valve Freezer compartment too warm or too cold Faulty valve Check valve function using the service mode Valve function faulty replace control unit and r...

Page 46: ...switch Always disconnect the refrigerator from the mains before working on the electrical system Electrical safety protection against contact must be ensured by the installation Cooling compartment il...

Page 47: ...2017 waa modified 28 09 2017 User Agent checked 28 09 2017 asan 47 61 Service manual Platform 2014 2016 V ZUG KT 1036497 00_ae gedruckt 6 Remove cover 7 Remove contact switch for door from front usin...

Page 48: ...l Platform 2014 2016 V ZUG KT 1036497 00_ae gedruckt 7 2 Replacing light Always disconnect the refrigerator from the mains before working on the electrical system Electrical safety protection against...

Page 49: ...otherwise contact will be faulty 6 To put back LED PCB reverse procedure 7 3 Replacing sensor F1 and F2 on display of operating unit Always disconnect the refrigerator from the mains before working on...

Page 50: ...cut a 100 mm length off it 4 Cut off 30 mm of white insulation Strip back approx 10 mm of black and brown stranded wire and prepare for new connection see image 5 Messen ob beide Litzen Durchgang hab...

Page 51: ...working on the electrical system Electrical safety protection against contact must be ensured by the installation 1 Remove operating panel with hinge cover Release operating panel from lock with screw...

Page 52: ...7 asan 52 61 Service manual Platform 2014 2016 V ZUG KT 1036497 00_ae gedruckt 7 5 Replacing door seal 1 Removing Lift seal at corners and remove 2 Mounting Carefully push seal in at corners and run f...

Page 53: ...97 00_ae gedruckt 7 7 Replace salad crisper in cold storage compartment EK1423 EA 5 Starting from right carefully push rear wall cover catches down according to image Using your left hand pull rear wa...

Page 54: ...497 00 AE 1 Serial production created 27 09 2017 waa modified 28 09 2017 User Agent checked 28 09 2017 asan 54 61 Service manual Platform 2014 2016 V ZUG KT 1036497 00_ae gedruckt 1 Slide salad crispe...

Page 55: ...ns and R600a hazard warnings Always replace desiccant cartridge When installing compressors in new or existing cooling systems all applicable safety regulations concerning the handling of flammable an...

Page 56: ...t indicated in blue and capillary tube for freezing compartment to refrigerant valve as shown in image capillary tube for main cooling compartment is shown on left 7 11 Replacing condenser Caution Onl...

Page 57: ...out after cooling circuit has been evacuated and flooded with nitrogen 1 Using special cutting tool cut off desiccant cartridge connections tight to desiccant cartridge 2 Remove desiccant cartridge 3...

Page 58: ...rter 3 Disconnect cable connections 4 Release fastening screws 5 Replace compressor 6 Tighten screws on compressor connect cable and put cover on inverter 7 Solder connections and desiccant cartridge...

Page 59: ...Serial production created 27 09 2017 waa modified 28 09 2017 User Agent checked 28 09 2017 asan 59 61 Service manual Platform 2014 2016 V ZUG KT 1036497 00_ae gedruckt 7 Solder connections and desicca...

Page 60: ...14 2016 V ZUG KT 1036497 00_ae gedruckt 4 Screw tight strain relief 5 Separate cable connection to compressor 6 Slot for earth connections green yellow cable 7 Slot for compressor contact black cable...

Page 61: ...com www vzug com Service manual 1036497 00 AE 1 Serial production created 27 09 2017 waa modified 28 09 2017 User Agent checked 28 09 2017 asan 61 61 Service manual Platform 2014 2016 V ZUG KT 103649...