Installation instructions

Range hood
Operating mode: Extraction/recirculation
DSMS

1030019-R04

10/05/2017

1

The appliance should be installed by qualified personnel only.
Each step must be carried out and checked in full in the order specified.

Validity

These installation instructions apply to:

64005

 (DSMS, construction width 11 cm)

General notes

If other firing systems are being used at the same time (e.g. wood, gas, oil or coal fired heating appliances), safe op-
eration is only possible providing a room negative pressure of 4 Pa (0.04 mbar) is not exceeded at the location of the
appliance.
Risk of toxic fumes! An adequate flow of fresh air must be guaranteed e.g. via non-closable openings in doors or
windows and in combination with an air-intake/exhaust-air wall box or by other technical means.

The use of the range hood together with a gas fired appliance is not permitted.

Efficient repairs can only be guaranteed if it is possible to de-install the complete appliance at any time without caus-
ing any damage.

Identification plate

The identification plate is located in the base unit on the side panel of the fan motor.

A second identification plate is included in the scope of delivery and should be retained for the purpose of appliance identifica-
tion.

Scope of delivery

S1 (12×)

M

U (2×)

E

S2 (4×)

A

T

F

G

N

L

T

V (2×)

R

K

A

Drip tray frame

N

Mains cable length 1.8 m

E

Control unit

Q

Flat channel system

F

Metal grease filter

R

Frame

G

Appliance housing

T

Exhaust air duct

K

Control cable

U

Spacer profile

L

Ventilation outlet

V

Connecting elements

M

Fan motor

Summary of Contents for DSMS

Page 1: ...openings in doors or windows and in combination with an air intake exhaust air wall box or by other technical means The use of the range hood together with a gas fired appliance is not permitted Effic...

Page 2: ...out by qualified personnel in accordance with the guidelines and standards for low voltage installations and the specifications of the local electricity supply companies A plug in appliance may only b...

Page 3: ...y means of flat channel or pipe 150 mm 3 Depending on the space available the position of the fan motor M can be adjusted by shortening the exhaust air ducting T 4 The control unit E can be positioned...

Page 4: ...t posi tion G4 30 11 30 cm 684 mm 667 mm 285 5 mm 398 5 mm 30 11 40 cm 787 mm 770 mm 285 5 mm 398 5 mm 40 11 40 cm 890 mm 873 mm 388 5 mm 501 5 mm 11 80 11 cm 993 mm 976 mm 114 5 mm 878 5 mm 40 11 40...

Page 5: ...70 mm 277 mm 390 mm 40 11 40 cm 873 mm 380 mm 493 mm 11 80 11 cm 976 mm 106 mm 870 mm 40 11 40 11 40 cm 1373 mm 380 mm 493 mm 880 mm 993 mm 40 11 60 11 40 cm 1560 mm 380 mm 493 mm 1067 mm 1180 mm 40 1...

Page 6: ...d installation with depth of 700 mm 900 1050 105 220 150 163 174 390 590 268 30 70 258 105 370 548 698 600 479 629 300 400 501 900 1050 105 220 150 163 174 390 590 268 30 70 258 105 370 548 698 700 47...

Page 7: ...uld be to the left or right Fasten frame R to housing G with 4 screws S1 S1 G R Insert metal grease filter F from the side into collection tray A Insert collection tray A from above into the hob hood...

Page 8: ...n K 99 118 8 5 8 5 507 490 R5 Optional Secure hob hood from below with 2 screws S1 as sembled ex factory tightening to a torque of 5 Nm S1 Prepare base according to intended installation variant Ex am...

Page 9: ...re is space is limited the ventilation outlet L can be re positioned To this end fan motor M is rotated see view above or converted see view below Feed the ventilation outlet L through one of the four...

Page 10: ...Fasten exhaust ducting T to hob hood with 4 screws S2 S2 4 All connection components must be cleaned and then com pletely sealed using suitable sealing tape or accessory H42067 Connect the appliance...

Page 11: ...l or pipe The diameter of the exhaust duct pipe must not be less than 150 mm The exhaust ducting should be as short and straight as possible Only use connection bend with large radii The exhaust ducti...

Page 12: ...ning is at least 500 cm e g base recess or lamella base If an exhaust air connection is not structurally possible the range hood must be set up for recirculation operation There is the fol lowing poss...

Reviews: