background image

19

Trouble-shooting

What to do if …

… the illumination is not working

 

… the appliance is not extracting enough air

 

Possible cause

Solution

Fuse or circuit breaker for 
electrical installations in 
the home is faulty.

A

Change the fuse.

A

Reset the circuit breaker.

Interruption in the power 
supply.

A

Check the power supply.

The halogen light is faulty.

A

Change the halogen light.

Possible cause

Solution

Grease filter is dirty.

A

Clean grease filter.

The activated charcoal 
filter (in the recirculaton 
model) is spent.

A

Change the activated charcoal filter.

Summary of Contents for DW-M9

Page 1: ...Range hood DW M9 DW M12 DI M10 DI M12 Operating instructions V ZUG Ltd...

Page 2: ...cal modifications for the purpose of the further development of the appliance is reserved Symbols used A Indicates step by step instructions Describes how the appliance reacts to the steps taken Indic...

Page 3: ...del 9 Fitted with 10 Construction 11 Operating and display elements 12 Use 13 Switching on 13 Switching off 13 After running time 13 Illumination 14 Grease filter saturation indicator 14 Care and main...

Page 4: ...Contents 4 Accessories and spare parts 20 Technical data 21 Disposal 22 Notes 23 Index 25 Repair service 27 Quick instructions 28...

Page 5: ...first time The appliance must be installed and connected up to the electricity supply in accordance with the separate installation instructions The necessary work should be done by a qualified fitter...

Page 6: ...necessary Use original spare parts only Retain these operating instructions for future reference If you sell or pass the appliance on to a third party please ensure these operating instruc tions toge...

Page 7: ...ping it below the temperature at which it can catch fire Change the cooking oil regularly dirty oil catches fire more easily than clean oil Clean the filters regularly Failure to do so can increase th...

Page 8: ...fresh air must be guaranteed e g via non closable openings in doors and windows and combined with ventilation wall bricks for incoming and exhaust air or by other technical means When carrying out ma...

Page 9: ...circulation model If for building reasons it is impossible to vent the air outside the appliance can be used as a recirculation model The cooking fumes and smells are fil tered over the metal grease f...

Page 10: ...e extraction fan has 4 power levels Low Medium High and Intensive level Power levels 1 3 can be used for longer periods of operation The intensive level is for shorter bursts of intensive extraction o...

Page 11: ...liance description 11 Construction 1 Operating and display elements 2 Metal grease filter 3 Halogen light 4 Hood 5 Activated charcoal filter for recirculating air only 6 Glass panel fold away 5 2 3 4...

Page 12: ...Power level 2 on off Power level 3 on off Intensive level on off After running time Illumination on off dimmed Grease filter saturation indicator Depending on the model and design the specification o...

Page 13: ...rently being used again After running time A Press the button to activate the after running time function With the after running time function the appliance runs for another 15 minutes and then switch...

Page 14: ...turation indicator The display illuminates after 15 operating hours or at the latest 14 days after first being put into operation The saturation level is reached The grease filter must be cleaned A Af...

Page 15: ...ease and condensate water can build up around the grease filter on the inside A Clean using a slightly damp cloth and detergent if necessary and wipe dry Take care that no water gets into the housing...

Page 16: ...ber A Pull down the grease filter and remove it A After cleaning reinstall the grease filter A Push glass panel upwards until it clicks into position on the left and right A After cleaning hold the bu...

Page 17: ...normal use they have to be replaced at least every four months They cannot be washed or regenerated A Push filter frame in direction of arrow A and re move in direction of arrow B A Replace the activa...

Page 18: ...max 20 watts A Clean the ring and the glass A Fit the ring and the glass back into the openings A Fold the glass panel up again A Put back screw fuse or switch on circuit breaker again Remove screw f...

Page 19: ...l installations in the home is faulty A Change the fuse A Reset the circuit breaker Interruption in the power supply A Check the power supply The halogen light is faulty A Change the halogen light Pos...

Page 20: ...ries and spare parts Please give model number and exact description when ordering parts Halogen light Metal grease filter Activated charcoal filter The halogen light is also available from specialist...

Page 21: ...21 Technical data Electrical connection A See identification plate A Remove metal grease filter The identification plate is located on the inside of the appliance...

Page 22: ...cket or have the appliance disconnected from the mains by a qualified electrician Then cut off the mains cable Disposal The old appliance should not be discarded as worthless rubbish If disposed of co...

Page 23: ...23 Notes...

Page 24: ...Notes 24...

Page 25: ...22 E Electrical connection 21 Extraction model 9 F Fittings 10 G Glass panel 11 Grease filter Cleaning 16 Saturation indicator 14 H Halogen light 11 Replacing 18 I Identification plate 21 Illuminatio...

Page 26: ...cautions Before using for the first time 5 Children in the home 6 Correct use 6 Note on use 7 Saturation indicator 14 Spare parts 20 Switching off 13 Switching on 13 Symbols 2 T Technical data 21 Trou...

Page 27: ...e or in your telephone or address book You will also find the same details on the certificate of guarantee the original sales invoice and the identification plate of the appliance A Remove metal greas...

Page 28: ...operating instructions Power level 1 on off Power level 2 on off Power level 3 on off Intensive level on off After running time Illumination on off dimmed Grease filter saturation indicator J787 352 3...

Reviews: